Schleuniger CCM 1200
27
Internal Circuit on the Wire Marker Output
The circuit on the wire marker output is structured as follows:
The output is designed for an induction load of up
to 0.2 A at 24 V DC (relay, valve) and is protected
against voltage surges.
Figure 7. Internal circuit on the wire marker
output
Electromagnetic Compatibility (EMC)
In order to meet the EMC regulations and consequently to reduce the affects of
interference, only cables made specially by Schleuniger may be used. In addition, the
interface connectors (D-Sub connectors) must be fixed with screws in accordance with
the regulations.
+ 24
1
2
4
5
Socket Wire Marker