The length of the base rails depends on the selected module width, maintenance 

aisle width and the number of module rows. 

The distance between "System Rail 18 at the bottom" and "System Rail 18 at the 

top" only depends upon the module inclination.  The first support should be 
placed at least 50 mm from the front edge of the base rail. The module frames are 
always flush at the top with the Rapid 16 module clamps.

The base rail length can be selected from the four standard lengths (2650, 
4200, 6000, 6300 mm) and combined with each other. The base rails can be 

connected with the internal connector, Item No. 129078-000. The maximum 
permissible field size has to be observed!

Mounting distances

Mounting Distances a and c as well as the lower projection of Modules b and d 
result from the module width. The dimensions can be determined as follows. 

Variant 13°

Variant 6°

The mounting times can be optimized by pre-assembling a series of base rails 

next to each other on mounting frames with the module supports.

Defining the base rail 
lengths and distances 
between module supports

maintenance walk 

way width

Distance a has to be adapted according to the width of the 

maintenance walk way.

The specification of the distances is based on the use of 

Rapid16 module clamps (module clamp length = 50mm).

module width

recommended 

maintenance 

walk way width: 

150mm

a = 1,94 x module width + 228

d = module width - 950

Detail A:

Distance c has to be adapted according to the width of the 

maintenance walk way.

The specification of the distances is based on the use of 

Rapid16 module clamps (module clamp length = 50mm).

c = 1,99 x module width + 211

recommended 

maintenance 

walk way width: 

150mm

module width

b = module width - 950

Detail A:

889

889

b

 = 1,97 x 

module width 

+ 208 mm

50

130 mm

b

A

36,0

30

40,0

10

Variant 

10

°

Detail: A

module width

recommended 

maintenance 

walk way width: 

Distance 

b

 has to be adapted according to the width of the 

maintenance walk way.

The specification of the distances is based on the use of 

Rapid16 module clamps (module clamp length = 50mm).

4

1

F

ix

Grid

18-100

 |  V

2

  |  

MO

UNTING INSTRUCTIONS

  |  20

18

11 

S C H L E T T E R   S O L A R   G M B H     |     S U B J E C T   T O   M O D I F I C A T I O N S

 

Summary of Contents for FixGrid18-100

Page 1: ...FixGrid18 100 MOUNTING INSTRUCTIONS...

Page 2: ...ning of your solar plant from the Schletter configurator Risk of breakage PV modules can be damaged if they are stepped on Planning of the solar power system installation and commissioning may only be...

Page 3: ...cific rules and regulations have to be observed Roof cleaning In order to ensure that the base rails are supported across their entire surface impurities such as moss leaves dirt stones etc have to be...

Page 4: ...n mounting frames with the module supports Defining the base rail lengths and distances between module supports maintenance walk way width Distance a has to be adapted according to the width of the ma...

Page 5: ...s Take into account a projection of the surface protection mat of at least 30 mm at the rail ends In the case of transversely flowing rainwater the distance has to be dimensioned on the basis of the a...

Page 6: ...ansversely draining roof water The permissible surface pressure of the roof has to be checked Sufficient drainage of rainwater has to be ensured Align base rails parallel to each other align the FixZ...

Page 7: ...to the alignment of the module row Apply the Rapid 16 end clamps at the top and at the bottom to the module and tighten Screws M8 T40 Place the module center clamp on the module do not tighten Connect...

Page 8: ...the base rails see Detail A Ballasting with additional trough see Detail B Ballasting with additional ballast shafts see Detail C Ballasting from the combination of the 3 possibilities The informatio...

Page 9: ...are turned 180 degrees recesses on the left from right to left The tray always lies with the side of the slots at the bottom and in the base rail with a positive fit At the last ballast tray the end h...

Page 10: ...0 0 SCHLETTER SOLAR GMBH Alustrasse 1 83527 Kirchdorf GERMANY www schletter group com We reserve the right to changes including technical modification 10...

Reviews: