![Schletter FixGrid18-100 Mounting Instructions Download Page 4](http://html1.mh-extra.com/html/schletter/fixgrid18-100/fixgrid18-100_mounting-instructions_1212726004.webp)
4 | 10
The length of the base rails depends on the selected module width, maintenance
aisle width and the number of module rows.
The distance between "System Rail 18 at the bottom" and "System Rail 18 at the
top" only depends upon the module inclination. The first support should be
placed at least 50 mm from the front edge of the base rail. The module frames are
always flush at the top with the Rapid 16 module clamps.
•
The base rail length can be selected from the four standard lengths (2650,
4200, 6000, 6300 mm) and combined with each other. The base rails can be
connected with the internal connector, Item No. 129078-000. The maximum
permissible field size has to be observed!
Mounting distances
Mounting Distances a and c as well as the lower projection of Modules b and d
result from the module width. The dimensions can be determined as follows.
Variant 13°
Variant 6°
The mounting times can be optimized by pre-assembling a series of base rails
next to each other on mounting frames with the module supports.
Defining the base rail
lengths and distances
between module supports
maintenance walk
way width
Distance a has to be adapted according to the width of the
maintenance walk way.
The specification of the distances is based on the use of
Rapid16 module clamps (module clamp length = 50mm).
module width
recommended
maintenance
walk way width:
150mm
a = 1,94 x module width + 228
d = module width - 950
Detail A:
Distance c has to be adapted according to the width of the
maintenance walk way.
The specification of the distances is based on the use of
Rapid16 module clamps (module clamp length = 50mm).
c = 1,99 x module width + 211
recommended
maintenance
walk way width:
150mm
module width
b = module width - 950
Detail A:
889
889
b
= 1,97 x
module width
+ 208 mm
50
130 mm
b
A
36,0
30
40,0
10
Variant
10
°
Detail: A
module width
recommended
maintenance
walk way width:
Distance
b
has to be adapted according to the width of the
maintenance walk way.
The specification of the distances is based on the use of
Rapid16 module clamps (module clamp length = 50mm).
4
1
F
ix
Grid
18-100
| V
2
|
MO
UNTING INSTRUCTIONS
| 20
18
11
S C H L E T T E R S O L A R G M B H | S U B J E C T T O M O D I F I C A T I O N S