![Schletter FixGrid18-100 Mounting Instructions Download Page 3](http://html1.mh-extra.com/html/schletter/fixgrid18-100/fixgrid18-100_mounting-instructions_1212726003.webp)
Mounting instructions
Risk of injury! People may be injured by falling objects. Before starting the
installation work, block off the danger zone and warn people in the vicinity.
Ensure that the flat roof waterproofing is compatible with the mounting system.
The roof drainage system has to be included in the planning of your solar plant.
In the case of very uneven roofs or roof waterproofing, compensatory measures
may have to be taken in order to ensure a uniform introduction of the load.
Necessary distances to roof edges have to be maintained.
The maximum field size depends on the type of roof.
For foil roofs, it is max. 10 m; for concrete roofs, it can also be larger in individual
cases.
In the case of roofs with substrate or gravel roofing, it has to be ensured that a
sufficiently non-slip connection occurs.
Please check the existing pitch of the roof and whether the mounting system has
to be secured against slipping.
The surface load is not permitted to exceed the residual load-bearing capacity of
the building!
The partial surface pressure, which acts on the roof membrane and insulation
under the base rails, is not allowed under any circumstances to exceed the
maximum permissible surface pressure.
Current country-specific rules and regulations have to be observed.
Roof cleaning! In order to ensure that the base rails are supported across their
entire surface, impurities such as moss, leaves, dirt, stones, etc. have to be
removed.
If there is a lightning protection system involved, it is important to determine
the extent to which integration by a certified lightning protection company is
necessary. Whether or not the lightning protection requirements change as a
result of the installation also has to be determined.
Due to static reasons, the installation of a single module row is not permitted!
Prior to installation, the roof has to be checked for damage of any kind,
particularly water beading or damage to the roof membrane. These should be
documented with photos in order to be able to counteract any recourse claims.
The system has been developed for modules with a width of 950-1050 mm
(standard module dimensions according to the current status). Other module
dimensions on request and separate verification. Information about module
clamping pursuant to the manufacturer has to be observed.
Use only original Schletter components!
Use the current mounting instructions! Accessible on our website:
www.schletter-group.com in the solar section under Downloads
F
ix
Grid
18-100
| V
2
|
MONTAGEANLEITUNG
| 20
18
11
S C H L E T T E R S O L A R G M B H | S U B J E C T T O M O D I F I C A T I O N S
2
F
ix
Grid
18-100
| V
2
|
MO
UNTING INSTRUCTIONS
| 20
18
11
S C H L E T T E R S O L A R G M B H | S U B J E C T T O M O D I F I C A T I O N S
3