L9000 FUNCTIONS
ANSI/BHMA A156.13, 1994, Series 1000, Grade 1
Keyed locks
Trim
assembly
page no.
Lock
assembly
page no.
Lock case
part no.
SCHLAGE ANSI Description
LV9077
Classroom security holdback lock† with Vandlgard
®
z
Latchbolt is retracted by knob/lever from either side unless locked by key from
either side. When locked, latchbolt is retracted by key outside or knob/lever
inside. Auxiliary latch deadlocks latchbolt when door is closed. Turn/depress
inside knob/lever and turn key 360° for holdback feature. Vandlgard function
allows exterior lever to rotate freely down while remaining securely locked.
L283-172
L9080 F07 Storeroom lock
z
Latchbolt is retracted by key outside or by knob/lever inside. Outside knob/lever
is always inoperative. Auxiliary latch deadlocks latchbolt when door is closed.
Inside knob/lever is always free for immediate exit.
L283-134
LV9080
Storeroom Lock with Vandlgard
®
z
Latchbolt is retracted by key outside or by knob/lever inside. Outside knob/lever
is always inoperative. Auxiliary latch deadlocks latchbolt when door is closed.
Inside knob/lever is always free for immediate exit. Vandlgard function allows
exterior lever to rotate freely down while remaining securely locked.
L283-173
L9080EL
Electrically locked (fail safe)
z
Outside knob/lever is continuously locked. Latchbolt is retracted by key outside
or by knob/lever inside. Switch or power failure allows outside knob/lever to
retract latchbolt. Auxiliary latch deadlocks latchbolt when door is closed. Inside
knob/lever is always free for immediate exit.
L283-142
LV9080EL
Electrically locked (fail safe) with Vandlgard
®
z
Outside knob/lever is continuously locked. Latchbolt is retracted by key outside
or by knob/lever inside. Switch or power failure allows outside knob/lever to
retract latchbolt. Auxiliary latch deadlocks latchbolt when door is closed. Inside
knob/lever is always free for immediate exit. Vandlgard function allows exterior
lever to rotate freely down while remaining securely locked.
L283-174
L9080EU
Electrically unlocked (fail secure)
z
Outside knob/lever is continuously unlocked. Latchbolt is retracted by key
outside or by knob/lever inside. Inside knob/lever is always free for immediate
exit. Auxiliary latch deadlocks latchbolt when door is closed.
L283-143
LV9080EU
Electrically unlocked (fail secure) with Vandlgard
�
z
Outside knob/lever is continuously unlocked. Latchbolt is retracted by key
outside or by knob/lever inside. Inside knob/lever is always free for immediate
exit. Auxiliary latch deadlocks latchbolt when door is closed. Vandlgard function
allows exterior lever to rotate freely down, while remaining securely locked.
L283-175
L9080EL-RX
Request to exit electrically locked (fail safe)
Same as L9080EL function. In addition, a microswitch
positioned inside the lock case is activated when either inside or outside knob/
lever is rotated. The switch signals the use of that opening to security systems,
allowing a non-disruptive means of immediate exit. Specify L283-263.
(Previously XL11-807)
L283-142
per
L283-263
†
Locks with holdback feature are not UL listed. Installation should be in accordance with existing codes only.
*
Caution: Double cylinder locks on residences–or on any door in any structure which are used for egress–are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
Not sold separately as a part.
z
Available with Request to Exit feature.
Summary of Contents for L9040