 AD-400 /AD-401 Networked Wireless Lock User Guide

OPTIONAL INSIDE PUSH BUTTON (IPB)

•  The inside push button (IPB) state is communicated to the access control panel by the

PIM400-485. The manner in which the network access control software utilizes this 
communication is confi gured at the host. The IPB may be used to communicate a lock/unlock 
request or be completely ignored by the network software.

•  AD-400 IPB activity will only be reported to control systems connected to a PIM400-485 with a 

RS-485 connection.

•  The IPB may be confi gured by the ACP or SUS to take direct action on the lock state in case 

communication from the control system to the AD-400 fails and the lock remains powered.

USER MANAGEMENT

User management is controlled by the access control system. If the access control panel has not yet 
been connected, use Construction Access Mode to add and delete users.

 

See Construction Access Mode on page 6 for more information.

For compliance with the UL Standards UL294 and ULCS319, the AD-400/AD-401 must be connected 
to an access control panel (ACP) that is UL listed for UL294 for UL installations and ULCS319 for 
cUL installations.

Summary of Contents for AD-400

Page 1: ...RELESS LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED WIRELESS LOCKS Para el idioma español navegue hacia www schlage com support Pour la portion française veuillez consulter le site www schlage com support P516 127 ...

Page 2: ...ations 11 Battery Failure Modes 12 External Power Supply 12 LED and Beep Reference 13 Troubleshooting 14 FCC IC Statements 16 www schlage com support 877 671 7011 To comply with FCC and Industry Canada RF radiation exposure limits for general population the antenna s used for this transmitter must be installed such that a minimum separation distance of 20 cm is maintained between the radiator ante...

Page 3: ... 12 for more information The outside lever is normally locked The inside lever always allows egress The AD 400 AD 401 normally operates in on line mode Information contained in the user credential is passed to an access control panel ACP which controls lock functions The ACP maintains the audit trail Outside Schlage Button Outside Lever Keyway Inside Inside Push Button IPB Optional Thumbturn Insid...

Page 4: ...e lock for proper mechanical and electronic operation See Test Lock Operation on page 8 for more information 6 Consult the SUS User Guide for information about configuring the lock and PIM400 7 Familiarize yourself with the information contained in this user guide Save this user guide for future reference SCHLAGE UTILITY SOFTWARE SUS The SUS is used to configure locks and the PIM400 When in a low ...

Page 5: ...to a PIM400 485 with a RS 485 connection The IPB may be configured by the ACP or SUS to take direct action on the lock state in case communication from the control system to the AD 400 fails and the lock remains powered USER MANAGEMENT User management is controlled by the access control system If the access control panel has not yet been connected use Construction Access Mode to add and delete use...

Page 6: ...ls Locks with Card Readers 1 Present the Master Construction Credential to the lock The Schlage button will light solid green for 20 seconds 2 Present the user credential to be added within twenty 20 seconds The user credential will be added to the lock database 3 The Schlage button will blink green on the left and right as confirmation 4 Repeat steps 1 and 2 for additional user credentials Creden...

Page 7: ...ps channel 3 9 If the link fails the Schlage button will blink red three 3 times and five 5 short beeps will sound The PIM400 will remain in link mode Carefully repeat steps 1 8 above If repeated LINK attempts fail change the frequency channel of the PIM400 and or move the PIM400 then repeat steps 3 7 10 Test the lock for normal operation See Test Lock Operation on page 8 for more information Re l...

Page 8: ...lay period default three seconds and the left side of the Schlage button will blink green When the lock re locks after the re latch delay period the left side of the Schlage button will blink red 3 If an invalid Construction Access user credential is presented the lock will beep and the left side of the Schlage button will blink red one time See Construction Access Mode on page 6 for more informat...

Page 9: ...The Schlage button and IPB will both light green for one second and a one second beep will sound to confirm that the lock has been reset If IPB is not pressed 3 times within 10 seconds two beeps with two red blinks indicate timeout 6 Replace the top inside cover Level 2 Factory Default Reset Level 2 factory default reset will delete all configurations and settings in the lock and the reader Reader ...

Page 10: ...rvention If test fails toggle Dynamic Channel Switching DCS to its opposite state off to on or on to off Then re link all locks and test again Cache Mode When enabled and communicating with the ACP the lock keeps a local database of successful access grants In the event of communication failure between the AD 400 AD 401 lock and PIM400 or between the PIM400 and the ACP access is enabled for facili...

Page 11: ...tions This product has been evaluated for ULC S319 compliance with Duracell Procell PC1500 AA alkaline batteries and Panasonic CR2025 lithium coin cell For installations requiring ULC S319 these battery models should be used Four Battery Configuration Eight Battery Configuration Low Battery Indications Replacement of batteries does not affect any programmed data Battery voltage can be checked with...

Page 12: ... locks and remains locked until batteries are replaced 1 Fail Unlocked and Fail Locked modes are not available if lock is externally powered EXTERNAL POWER SUPPLY The AD 400 AD 401 may be connected to external power using a UL294 listed Power Supply for UL installations and a power supply that complies with CAN UL S318 or CAN ULC S319 for cUL installations The power supply must be capable of sourc...

Page 13: ...ide for more information Action Schlage Button LEDs Beeps Extended Toggle unlock 2 Green 0 Card presented and not read None 0 Card presented and read None 1 No frequency communication with PIM400 or the ACP when card presented 1 Red 0 Access denied Controlled by ACP via PIM400 Access granted momentary unlock motor runs 1 Green 0 Relock motor runs 1 Red 0 ...

Page 14: ...pid beeps OR PIM400 SUS Diagnostics shows the door status as not linked The lock and the PIM400 are not linked The PIM400 is not in link mode before the link procedure An incorrect door number was selected when linking the AD 400 AD 401 The Wireless Communication Module is not properly installed The AD 400 AD 401 is located too far away from the PIM400 Data transmission to the access control panel...

Page 15: ... Use default for all Magnetic Card Credential Readers is Track2 The magnetic swipe card data may be on Track1 or Track3 Check that the through hole ribbon cable is not pinched Change the Smart card format using the SUS Select AD 400 AD 401 Lock Properties Reader tab and Smart cards in use Use the SUS to change Mag Track in Use Select AD 400 AD 401 Lock Properties Reader tab and MAG Card Track sele...

Page 16: ...r Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interfer...

Reviews: