Installation and commissioning DATAEAGLE 3XXX X-treme
CAUTION
Chapter 4
– Installation of new devices
PE has to be connected with control cabinet round! If the
PE is not connected the noise filter cannot filter interfer-
ences on 9-33V DC power supply line. These may cause
malfunctions, errors or the destruction of the device.
Supply source needs to be in compliance with SELV and
LPS output according UL/IEC 60950-1 or ES1 and PS2
output according UL/IEC 62368-1.
A self-healing 0,7A fuse is integrated into the input
circuit. This fuse cannot be exchanged. The device has
to be disconnected from the power supply for approx. 2
minutes after the fuse has been triggered. Ensure that
the power supply provides 9 to 33 V DC before you
switch on the supply voltage.