15
Installation Instructions
Anchor Plate
Fig. 1
Lip Seal x 2
( T200 P1
applications only)
Insulation
Joint Band
Adjustable Pipe
Joint
Band
ADJUSTABLE PIPE
The adjustable pipes are delivered as two pre-assembled sections with a joint band and locking
band (see Fig.1). They are used with standard components to achieve an exact length on site
and avoid on-site cutting of components.
1.
Calculate the length required. Loosen the joint band and remove the top section of the
adjustable pipe.
2.
Remove insulation as required to achieve the correct length.
3.
Re-assemble the pipe and cover the joint with the joint band.
4.
Fix the adjusted section to standard components using the locking band provided.
Please note that the adjustable pipe is non load bearing.