Appendix 1: 

Typical electrical data under standard test conditions

 

Module type   

Scheuten Fusion P6-60 U 

 

220W* 

225W 

230W 

235W 

240W* 

Rated output

 

220 

235 

210 

215 

240 

Power range

 

+0/+5 

+0/+5 

+0/+5 

+0/+5 

+0/+5 

Power density

 

136 

139 

142 

145 

149 

Mpp voltage

 

29,1 

29,6 

30,0 

30,5 

31,0 

Mpp Current

 

7,56 

7,61 

7,66 

7,70 

7,75 

Open circuit voltage

 

37,2 

37,6 

38,0 

38,5 

38,9 

Short-circuit current

 

8,14 

8,16 

8,17 

8,19 

8,20 

Module efficiency reduction @ 200 W/m

2

  -0.8% Abs. 

* 220 and 240 Wp are available only in limited quantities 

The electrical characteristics are within ±5 percent of the indicated values of Isc, Voc, and Pmax under  
standard test conditions (irradiance of 100 mW/cm2, AM 1.5 spectrum, and a cell temperature of 25°C (77°F)). 

Permissible operating conditions: 

Temperature range 

-40 °C up to 85 °C   (-40 °F up to 185 °F) 

Maximum system voltage 

600 V 

Reverse current rating 

15 A (in accordance with IEC 61730-2) 

UL certified design load 

75 PSF (3600 Pascal) 

 
Recommended number of modules for series connection 

12 

Recommended number of modules for parallel connection 

Only modules of the same output class may be connected to each other. 
UL listed line fuses must be sized according to the reverse current rating. 

Other details at a glance:

 

Dimensions H x W x D 

1637 x 987 x 40 (in mm)   64.45 x 38.86 x 1.57 (in inch) 

Weight 

18.5 kg, 41 lbs 

Module design 

Glass / EVA / cells / EVA / rear panel cover (composite foil) 

Cells 

60 x 6" (square in shape, edge length 156 mm (6.09 inch)), polycrystalline 

Frame 

Anodised, made of aluminium extruded profiles 

Glass 

3.2 mm (0.125”) single-layer safety glass, highly transparent, low iron 

Junction box 
Dimensions H x W x D 
Connector 

Tyco 1-1394723-8 
150x150x25 (in mm), 5.90x5.90x0.98 (in inch)  
Tyco

 6-1394461-2(male)/0-1394462-4(female) 

NBZH PV-ZH010 
138x105x31 (in mm), 5.34x4.13x1.22 (in inch)  
NBZH PV-ZH202 

Bypass diodes 

3 Diotec SB1240 diodes   

Module cable 

2 x 6 mm² (0.0093 inch

2

), black, dual insulation, UV resistant, 1500 mm (59”) 

 
 
 
 
 

Summary of Contents for Solar Fusion P6-60 U

Page 1: ...sk of electric shock Do not stand on drop scratch or allow objects to fall on modules Do not install or handle the modules when they are wet or during periods of high wind The applicable regulations pertaining to work safety accident prevention and securing the construction site must be observed Persons and objects have to be secured against falling Any third party need to be protected against inj...

Page 2: ...hould be drilled into the unit for mounting purposes for potential equalization or for any other purposes Any changes of this kind will void the warranty 3 0 Electrical Installation Danger Risk of death or serious injury from electric shock Do not connect or disconnect modules under load Scheuten PV modules may be used in systems that are accessible without restrictions if installed in accordance ...

Page 3: ...nding Lug Lay In Lug Ilsco GBL 4DBT Bolt 6 32 SS McMaster Carr 92314A148 Serrated Washer M5 SS McMaster Carr 91120A140 Washer ID 9 64 OD 3 8 SS McMaster Carr 92141A007 Nut 6 32 SS McMaster Carr 91841A007 See www ilsco com www mcmaster com Scheuten Solar recommends using a UL listed lay in ground lug such as IIsco GBL 4DBT or equivalent and stainless steel hardware bolt washer serrated washer and n...

Page 4: ...to 85 C 40 F up to 185 F Maximum system voltage 600 V Reverse current rating 15 A in accordance with IEC 61730 2 UL certified design load 75 PSF 3600 Pascal Recommended number of modules for series connection 12 Recommended number of modules for parallel connection 3 Only modules of the same output class may be connected to each other UL listed line fuses must be sized according to the reverse cur...

Page 5: ...pressure load psf 4 Clamps at long side Mounting holes A B 4 75 75 112 5 4 Clamps at long side Mounting holes A 4 B 12 and clamps separation 31 5 33 50 50 75 4 Clamps at long side Corner 4 50 50 75 4 Clamps at short side Corner 4 50 50 75 Line support on short side Short side Full support 50 50 75 Recommendations for mounting clamps C A B B Alternative clamping methods Length inch 2 6 Min frame ov...