Scheppach 5906223903 Translation Of Original Instruction Manual Download Page 9

www.scheppach.com

24 | GB

•  Push the choke lever (13) back after starting the en-

gine.

Warm state

• 

Set the on/of switch (10) to the “ON” position

• 

Turn the tank ventilation (1) to the “ON” position.

• 

Turn the fuel valve (11) to the “ON” position.

• 

Use the start pull cord (12) to start the engine; to do 
so, pull the handle forcefully.

 

If the engine does not 

start, pull on the handle again.

ATTENTION! 

This socket may be loaded with 1000 W 

continuously (S1) and with 1020 W for a short time (S2) 

for a maximum of 5 minutes. 

Note: Some electrical devices (motorised jigsaws, drills, 
etc.) can have high power consumption if they are used 
under diicult conditions.

Switch of the engine (Fig. 1)

Allow the power generator to run for a short time with-

out load before switching it of so that the unit can “cool 
down”.

• 

Set the on/of switch (10) to the “OFF” position.

•  Close the fuel valve (11).

Connection to alternating current (AC)

•  Allow the generator to run for a few minutes before 

connecting electrical devices.

• 

Do not exceed the load capacity of the generator by 

connecting more electrical devices than the device 

can handle.

• 

Do not switch on electrical devices until they are con

-

nected to the generator.

Tip

:  If  the  generator  is  connected  to  several  loads  or 

power consumers, please remember to connect the one 

with the highest starting current irst. and the one with 

the lowest starting current last.

Overload indicator (6)

The overload protection becomes active if the power 

consumption  is  too  high  and  switches  of  the  230  V 

socket (4).

• 

Switch the device of.

• 

Reduce the total wattage of the connected electrical 

devices to the rated power.

• 

Check the air ilter for contamination.

 

If contamina

-

tion is detected, remove it. 

(see air ilter)

•  Put the device back into operation.

•  Fill storage tank with fuel.

• 

Close the tank by turning the tank cover (2) clock

-

wise.

Recommended fuel

Only  unleaded  regular  petrol  with  a  research  octane 

rating of 91 or higher is required for this engine. 

Only use fresh, clean fuel.

Water or impurities in the petrol damage the fuel sys

-

tem.

Refuel in a well-ventilated area with the en-

gine stopped.  If the engine was in opera-

tion  immediately  before,  allow  it  to  cool  irst.

  

Never refuel the engine in a building where the 

fuel vapour may come into contact with lames or 

sparks.

Petrol is highly inlammable and explosive.

 When 

handling fuels, you may sufer burns or other se

-

vere injuries.

• 

Switch  of  the  engine  and  keep  it  away  from  heat, 
sparks and lames.

• 

Only refuel outdoors.

• 

Mop up spilled petrol immediately.

Earthing (Fig. 1)

Earthing  the  housing  is  necessary  to  discharge  static 

charging. To do this, connect a cable on one side to the 

earth terminal (8) of the power generator and on the oth-

er side to an external mass rising pipe (e.g. rod earth).

10.  Start up

m

 Attention!

Always make sure the device is fully assembled 

before commissioning!

Start the engine (ig. 1)

ATTENTION! 

When starting with the start pull cord 

(12), injuries to the hand can occur due to sudden kick-

back. 

Wear protective gloves for starting.

Cold state

• 

Set the on/of switch (10) to the “ON” position.

• 

Turn the tank ventilation (1) to the “ON” position.

• 

Carefully push the choke lever (13) to the right as far 

as it will go.

• 

Turn the fuel valve (11) to the “ON” position.

• 

Use  the  start  pull  cord  (12)  to  start  the  engine; 
to  do  so,  pull  the  handle  forcefully.

 

If  the  en

-

gine does not start, pull on the handle again. 

Summary of Contents for 5906223903

Page 1: ...Z Invertorov elektrick gener tor P eklad origin ln ho n vodu k obsluze 88 SK Invertorov elektrick gener tor Preklad origin lneho n vodu na obsluhu 99 HU Inverteres ramfejleszt Eredeti haszn lati utas...

Page 2: ...www scheppach com 2 1 1 2 3 4 5 6 7 11 12 13 14 9 10 8...

Page 3: ...www scheppach com 3 2 3 4 5 6 15 16 17 18 a 19 e 21 d c f 2 20 0 6 0 7mm 7 b...

Page 4: ...3 Scope of delivery 20 4 Proper use 20 5 General safety information 21 6 Residual risks 22 7 Technical data 22 8 Unpacking 23 9 Before commissioning 23 10 Start up 24 11 Electrical connection 25 12 C...

Page 5: ...the applicable product liability laws the manufacturer of this device assumes no liability for damage to the device or caused by the device arising from Improper handling Non compliance with the opera...

Page 6: ...for 2 5 mm 17 Never operate the power generator during rain or snowfall 18 Always switch of the engine during transport and refuelling Other general occupational health and safety related rules and r...

Page 7: ...22 Place the power generator at least 1 m away from walls or connected devices 23 Keep children away from the power generator 24 Values speciied in the technical data under sound power level LWA and s...

Page 8: ...he oil level without screwing the dipstick tight again The oil level must be within the middle mark on the oil dipstick If the oil level is too low add some oil Then screw the oil dipstick 21 in again...

Page 9: ...devices to the rated power Check the air ilter for contamination If contamina tion is detected remove it see air ilter Put the device back into operation Fill storage tank with fuel Close the tank by...

Page 10: ...r maintenance work switch of the engine and remove the spark plug connec tor b from the spark plug Tip The overload indicator lamp may initially light up for a few seconds when using electrical equipm...

Page 11: ...ts are required as consuma bles Wearing parts Spark plug may not be included in the scope of supply m ATTENTION Danger of burning Wait until the device has cooled down before cleaning or maintenance m...

Page 12: ...cates that this product must not be disposed of together with domestic waste in compliance with the Directive 2012 19 EU pertaining to waste electrical and electronic equipment WEEE This product must...

Page 13: ...op Fault Possible cause Remedy Generator does not start Automatic oil cut of starts Check oil level ill with engine oil as necessary Spark plug sooty Clean or replace spark plug Check electrode gap No...

Page 14: ...ppoint pendant le fonctionnement Important Les gaz d chappement sont nocifs Par cons quent vous ne devez pas faire fonctionner le moteur dans des zones non ventil es Portez une protection auditive Por...

Page 15: ...www scheppach com 221...

Page 16: ...M GENERATOR Y ENGINE BRIDGE RECTIFIER SPARK PLUG HIGH VOLTAGE SET ON OFF TRIGGER OIL SENSOR FRAME CONTROL PANEL IGNITOR AC OUTPUT DC PROTECTOR DC SOCKET INVERTER ECO MAX SWITCH STEP MOTOR DC WIDING AC...

Page 17: ...June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est conforme aux r glementations de la d...

Page 18: ...from 8th June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est conforme aux r glementations...

Page 19: ...n Parliament and Council from 8th June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est con...

Page 20: ...re dalla consegna in maniera tale che sostituiamo gratuitamente qualsiasi componente che entro tale periodo presenti dei vizi di materiale o di fabbricazione tali da renderlo inutilizzabile Per compon...

Page 21: ...n m pr slu n rok na z ru n pln nie k subdod vate ovi Za trovy t kaj ce sa in tal cie novej s iastky je zodpovedn z kazn k N rok na v menu tovara na z avu a in n roky na nahradenie kody s vyl en Szavat...

Page 22: ...Attiec b uz rezerves da m kuras nav m su ra otas m s garant jam tikai gad jum ja mums ir garantija no saviem pieg d t jiem Jauno deta u uzst d anas izmaksas ir j uz emas pirc jam Pirkuma atcel ana vai...