Scheppach 5906223903 Translation Of Original Instruction Manual Download Page 8

www.scheppach.com

GB | 23 

• 

When ordering please provide our article number as 
well as type and year of manufacture for your equip

-

ment.

m

 WARNING! 

The device and the packaging material are not 

children’s toys! Do not let children play with plas-

tic bags, ilms or small parts!

 There is a danger of 

choking or sufocating!

9.  Before commissioning

ATTENTION!

Check before starting the engine:

• 

Check fuel level, top up if necessary

 

- the tank should be at least half-full

• 

Ensure the device has suicient ventilation

• 

Make sure that the ignition cable is attached to the 

spark plug

• 

Disconnect  any  connected  electrical  devices  from 

the power generator

• 

The condition of the air ilter,

•  The condition of the fuel lines,

• 

The irm seating of the external screw connections,

m

 Attention!

 

Fill the oil before irst use.

Before each use, check the oil level with the engine 

switched  of  and  on  a  level  surface.

 

Use  the  highest 

quality four-stroke oil or an HD oil with the same level 
of  quality.

 

SAE  10W-30  is  recommended  for  general 

use at all temperatures.

Check the oil level (Fig. 3, 4)

•  Place the generator on a level, even surface

• 

Open the engine cover (19) by loosening the Phillips 

screw (a).

• 

Unscrew the oil dipstick (21).

•  Fill the tank with engine oil using the funnel (15). 

Note the max. illing capacity of 250 ml. Carefully ill 
the oil up to the lower edge of the iller neck.

• 

Wipe the oil dipstick (21) with a clean, lint-free cloth.

• 

Re-insert the oil dipstick (21) and check the oil level 

without screwing the dipstick tight again.

•  The oil level must be within the middle mark on the 

oil dipstick.

• 

If the oil level is too low, add some oil.

•  Then screw the oil dipstick (21) in again.

Fill with fuel

• 

In order to refuel the device, open the tank cover (2) 
by turning it anti-clockwise.

Drive motor type

4-stroke 1 cylinder 

 

air-cooled

Displacement

53,5 cm

3

Max. power (engine)

 

1.5 kW / 2 HP

Fuel

Unleaded petrol (min. 98 

octane)

Tank contents 

4 l

Engine oil type

10W30 / 15W40

Oil volume (approx.)

250 ml

Consumption at full 
load

1,05 l/h

Max. temperature.

40 

°

C

Max. altitude (above 

mean sea level)

1000 m

Spark plug

A7RTC

Performance class

G1

Weight

13 kg

Technical changes reserved!

Noise and vibration

Warning

:  Noise  can  have  serious  efects  on  your 

health. 

If the machine noise exceeds 85 dB (A), please 

wear suitable hearing protection.

Noise data

Sound power level L

WA

 

92.9 dB(A) 

Sound pressure level L

pA

 

72.6 dB(A)

Uncertainty K

wa/pA

 

2 dB(A)

8.  Unpacking

• 

Open  the  packaging  and  carefully  remove  the  de

-

vice.

• 

Remove the packaging material, as well as the pack

-

aging and transport safety devices (if present).

• 

Check whether the scope of delivery is complete.

• 

Check the device and accessory parts for transport 

damage. 

In the event of complaints the carrier must 

be  informed  immediately.

  Later claims will not be 

recognised.

• 

If possible, keep the packaging until the expiry of the 
warranty period.

• 

Familiarise yourself with the product by means of the 
operating instructions before using for the irst time.

• 

With  accessories  as  well  as  wearing  parts  and 
replacement  parts  use  only  original  parts.

 

Re

-

placement parts can be obtained from your dealer.

 

Summary of Contents for 5906223903

Page 1: ...Z Invertorov elektrick gener tor P eklad origin ln ho n vodu k obsluze 88 SK Invertorov elektrick gener tor Preklad origin lneho n vodu na obsluhu 99 HU Inverteres ramfejleszt Eredeti haszn lati utas...

Page 2: ...www scheppach com 2 1 1 2 3 4 5 6 7 11 12 13 14 9 10 8...

Page 3: ...www scheppach com 3 2 3 4 5 6 15 16 17 18 a 19 e 21 d c f 2 20 0 6 0 7mm 7 b...

Page 4: ...3 Scope of delivery 20 4 Proper use 20 5 General safety information 21 6 Residual risks 22 7 Technical data 22 8 Unpacking 23 9 Before commissioning 23 10 Start up 24 11 Electrical connection 25 12 C...

Page 5: ...the applicable product liability laws the manufacturer of this device assumes no liability for damage to the device or caused by the device arising from Improper handling Non compliance with the opera...

Page 6: ...for 2 5 mm 17 Never operate the power generator during rain or snowfall 18 Always switch of the engine during transport and refuelling Other general occupational health and safety related rules and r...

Page 7: ...22 Place the power generator at least 1 m away from walls or connected devices 23 Keep children away from the power generator 24 Values speciied in the technical data under sound power level LWA and s...

Page 8: ...he oil level without screwing the dipstick tight again The oil level must be within the middle mark on the oil dipstick If the oil level is too low add some oil Then screw the oil dipstick 21 in again...

Page 9: ...devices to the rated power Check the air ilter for contamination If contamina tion is detected remove it see air ilter Put the device back into operation Fill storage tank with fuel Close the tank by...

Page 10: ...r maintenance work switch of the engine and remove the spark plug connec tor b from the spark plug Tip The overload indicator lamp may initially light up for a few seconds when using electrical equipm...

Page 11: ...ts are required as consuma bles Wearing parts Spark plug may not be included in the scope of supply m ATTENTION Danger of burning Wait until the device has cooled down before cleaning or maintenance m...

Page 12: ...cates that this product must not be disposed of together with domestic waste in compliance with the Directive 2012 19 EU pertaining to waste electrical and electronic equipment WEEE This product must...

Page 13: ...op Fault Possible cause Remedy Generator does not start Automatic oil cut of starts Check oil level ill with engine oil as necessary Spark plug sooty Clean or replace spark plug Check electrode gap No...

Page 14: ...ppoint pendant le fonctionnement Important Les gaz d chappement sont nocifs Par cons quent vous ne devez pas faire fonctionner le moteur dans des zones non ventil es Portez une protection auditive Por...

Page 15: ...www scheppach com 221...

Page 16: ...M GENERATOR Y ENGINE BRIDGE RECTIFIER SPARK PLUG HIGH VOLTAGE SET ON OFF TRIGGER OIL SENSOR FRAME CONTROL PANEL IGNITOR AC OUTPUT DC PROTECTOR DC SOCKET INVERTER ECO MAX SWITCH STEP MOTOR DC WIDING AC...

Page 17: ...June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est conforme aux r glementations de la d...

Page 18: ...from 8th June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est conforme aux r glementations...

Page 19: ...n Parliament and Council from 8th June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment L appareil d crit ci dessus dans la d claration est con...

Page 20: ...re dalla consegna in maniera tale che sostituiamo gratuitamente qualsiasi componente che entro tale periodo presenti dei vizi di materiale o di fabbricazione tali da renderlo inutilizzabile Per compon...

Page 21: ...n m pr slu n rok na z ru n pln nie k subdod vate ovi Za trovy t kaj ce sa in tal cie novej s iastky je zodpovedn z kazn k N rok na v menu tovara na z avu a in n roky na nahradenie kody s vyl en Szavat...

Page 22: ...Attiec b uz rezerves da m kuras nav m su ra otas m s garant jam tikai gad jum ja mums ir garantija no saviem pieg d t jiem Jauno deta u uzst d anas izmaksas ir j uz emas pirc jam Pirkuma atcel ana vai...

Reviews: