www.scheppach.com /
+(49)-08223-4002-99 /
+(49)-08223-4002-58
26 | GB
Then draw out the air filter housing (1). Draw the air
filter housing (1) apart. You can now remove the air
filter. Carefully knock out the air filter and the parts of
the filter housing.
These components must then be blown out with com-
pressed air (approx. 3 bar) and reassembled in re
-
verse order.
15.7 Connections and repairs
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the
event of any enquiries:
•
Type of current for the motor
•
Machine data - type plate
•
Motor data - type plate
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Air filters, belts, cylinders, pistons, pis
-
ton rings, plastic clips
* Not necessarily included in the scope of delivery!
16. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip
-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective com-
ponents must be disposed of as special waste. Ask
your dealer or your local council.
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical and
electronic equipment (WEEE). This product must be
disposed of at a designated collection point. This can
occur, for example, by handing it in at an authorised
collecting point for the recycling of waste electrical
and electronic equipment. Improper handling of waste
equipment may have negative consequences for the
environment and human health due to potentially
hazardous substances that are often contained in
electrical and electronic equipment. By properly dis
-
posing of this product, you are also contributing to the
effective use of natural resources.
Do not use the compressor with a damaged or rusty
pressure vessel. If you discover any damage, then
please contact the customer service workshop.
m
Important!
The condensed water from the pressure vessel will
contain residual oil. Dispose of the condensed water
in an environmentally compatible manner at a suita
-
ble collection point.
15.3 Safety valve (Fig. B)
The safety valve (20) has been set for the highest
permitted pressure of the pressure vessel.
It is prohibited to adjust the safety valve or re-
move its seal.
15.4 Checking the oil level at regular intervals
(fig. F)
Place the compressor on a level and straight surface.
The oil level must be at the centre of the oil sight glass
(16) (red dot).
15.5 Changing the oil (Fig. L)
The first oil filling must be changed after 100 oper
-
ating hours; afterwards perform an oil change every
500 operating hours.
Switch the motor off and unplug the mains plug from
the power outlet. Remove the oil drain plug (15). Ad
-
ditionally open the oil sealing plug (18).
To prevent the oil from running out in an uncontrolled
manner, hold a small metal chute under the opening
and collect the oil in a vessel. If the oil does not drain
out completely, we recommend tilting the compressor
slightly.
When the oil has drained out, re-fit the oil drain plug
(15).
Dispose of the old oil at a drop-off point for old oil.
To fill in the correct quantity of oil, make sure that the
compressor stands on an even surface. Remove the
oil sealing plug (18) and add new oil through the oil
filler opening, until the oil level in the oil sight glass
(16) has reached the correct quantity (red dot).
Do not exceed the maximum filling quantity. Overfill
-
ing the equipment may result in damage.
Reinsert the oil sealing plug (18) in the oil filler open
-
ing.
15.6 Cleaning the air filter
The air filter prevents dust and dirt being sucked in.
It is necessary to clean this filter at least every 300
operating hours.
A blocked air filter significantly reduces the compres
-
sor power.
Remove the air filter by opening the wing nut (32) on
the air filter housing (1). Remove the wing nut (32) and