![Scheppach 5807802986 Original Operating Manual Download Page 21](http://html.mh-extra.com/html/scheppach/5807802986/5807802986_original-operating-manual_1210920021.webp)
www.scheppach.com
+(49)-08223-4002-99
+(49)-08223-4002-58
21 І 24
www.scheppach.com
+(49)-08223-4002-99
+(49)-08223-4002-58
Old devices must not be disposed of
with household waste!
This symbol indicates that this product
must not be disposed of together with
domestic waste in compliance with
the Directive (2012/19/EU) pertaining
to waste electrical and electronic equipment
(WEEE). This product must be disposed of
at a designated collection point. This can
occur, for example, by handing it in at an
authorised collecting point for the recycling
of waste electrical and electronic equip-
ment. Improper handling of waste equip-
ment may have negative consequences for
the environment and human health due to
potentially hazardous substances that are
often contained in electrical and electronic
equipment. By properly disposing of this
product, you are also contributing to the ef-
fective use of natural resources. You can
obtain information on collection points for
waste equipment from your municipal ad-
ministration, public waste disposal authority,
an authorised body for the disposal of waste
electrical and electronic equipment or your
waste disposal company.
13. Possible faults
Problem
Possible cause
Remedy
Motor does not start.
No power supply (power failure)
Check fuses
Mains cable defective.
Exchange defect cable,
respectively check extension
cable, (by electrician)
Never use defect lead
Motor or switch defect
To correct the problem, refer
to the manufacturer or other
approved service centre.
Unusual vibrations
Beater defective.
Replace the beater.
Chuck defective.
To correct the problem, refer
to the manufacturer or other
approved service centre.
Non-intended material to be
mixed.
Incorrect processing. Follow the
processing instructions from the
supplier.
Device starts but blocks
under slight load and
cuts off automatically.
Extension cable too long, or
crosssection too small.
Extension cable at least 1,5 mm
2
,
maximum 25 m long.
Socket too far away from main
connection, and cross-section of
connection lead too small.
Cross- section of at least 2,5 mm
2
in longer cables.