18
The flame monitor evaluates the flame on the basis of its
flicker frequency. This is done optically by the light tube
end piece of the mixing device.
Display of the operating status:
LED off
Flame detector not active
LED flashes
Safety test carried out, flame monitor active, no flame present
LED lights up flickering
Safety test completed, flame monitor active, flame present
Flame detector
(This item is omitted for the Micro variants)
Oil hoses
(pair)
Item No.
Flame detector
020064
Burner components for MH series and MH micro
Item No.
MH
0414180
MH Micro
0414110
The release button is the central element for
release, activation / deactivation and diagnosis.
The multi-coloured signal light in the release
button is the central display element for visual
diagnosis and interface diagnosis. During opera-
tion, the various states are displayed in the form
of colour codes according to the colour code
table.
Item No.
MH 10/17
0201020
MH 15/23
MH 30/40
0201026
MH micro
0201029
Control unit
Summary of Contents for 077480