12
overview MH Micro
control box
air vent
oil filter
heating
water
exhaust gas 35 mm
fresh air supply 75 mm
Output domestic
water
Mixer for adjusting the flow temperature of the heating water
(oil filter and metal flap are to be dismantled)
Input domestic
water
max. flow rate of heated
domestic water must be set
before commissioning
Side view
VORSICHT:
Bei den MH micro-Varianten ist unbedingt zu beachten:
1.
The max. flow rate of heated domestic water must be set with the supplied key before commissioning. The
opening must then be closed again.
2.
the micro variants are intended exclusively for open (unpressurised) systems. An expansion vessel is not
required. The maximum operating pressure of 0.5 bar must be observed.
3.
when heating the machine (optional), the user must ensure that temperatures in the heating system do not
exceed 75°C.
4.
Potential equalisation must be established with a connection between the heating system and the vehicle
body. The connection must be made by a cable connection at the screw marked on the heating system and a
cable of at least 4 mm².
Resetbutton for the burner
Wasserheizgerät MH micro
Type / Model
Power
Item No.
MH 10 micro
10 kW
0774820
MH 20 micro L
20 kW
07480
Front view
Summary of Contents for 077480
Page 31: ......