Einstellanleitung Elektronikmotor-Studio Star_englisch.docx
Stand: 13.01.16
Seite 9 von 16
3. Setting Instructions - Type: GU, SU, GSU, SIU, SIGU, RU
The drive has 4 different switching modes, the selection takes place automatically via the setting.
3.1. Overview Off-Mode 1
Upper and lower end position about torque detec-
tion
(shutter moves against the stop).
Both end position stops are being readjusted automati-
cally.
Note:
This mode is suitable only with solid shaft connectors
and not for the Schanz special profile
3.2. Overview Off-Mode 2 – Standard for type GU
Upper end position about torque detection
(shutter moves against the stop) / set end position
bottom.
The upper end position is being readjusted automatical-
ly, the lower end position stays fix.
3.3. Overview Off-Mode 3
Set end position at the top
/ lower end position
about torque detection (shutter moves against the
stop)
The upper end position is being readjusted automatical-
ly, the lower end position stays fix.
Note:
This mode is suitable only with solid shaft connectors
and not for the Schanz special profile.
3.4. Overview Off-Mode 4
Set end position at the top
/ set end position bottom
An automatic readjustment does not take place.
Important!
Adhere to the sequence, first the upper and then the lower float stop has to be
teached.