1. Setting the drive into learning mode
1.1. Setting with test cable
Step No.
Operation
Note
Check
The motor is delivered in learning mode. If a fault occurs during the programming or if an already programmed drive
should be installed in a different position or changes were made to the roller shutter, then the drive can be set again
into learning mode. All defined values will be deleted.
Therefore and for setting the endpoints in mode 2-4 a special test cable is necessary so that UP and DOWN can be
pressed simultaneously.
10
Press either both buttons or the programming button* for at least
6 sec. until the drive twitches once.
If the drive is already in learning mode a second twitch occurs af-
ter approx. 1 sec. This has to be ignored.
Note:
This step can be ignored when setting the roller shutter for the
first time as the drive is in learning mode upon delivery.
*Depending on test cable model
1.2. Setting with micro switch and switch
Step No.
Operation
Note
Check
The motor is delivered in learning mode. If a fault occurs during the programming or if an already programmed drive
should be installed in a different position or changes were made to the roller shutter, then the drive can be set again
into learning mode. Besides all values are deleted.
10
Keep the button in the micro-switch pressed.
Keep the UP or DOWN button pressed for 6 sec. until the drive
twitches once.
If the drive is already in learning mode a second twitch occurs af-
ter approx. 1 sec. This has to be ignored.
If the drive does not move, release the micro-switch and bring the
control switch back in the neutral position.
Then again keep the button in the micro-switch pressed and
press the other UP or DOWN button for 6 sec. until the roller
shutter slat twitches once.
The button that functions is from now the active button. For