Einstellanleitung Elektronikmotor-Studio Star_englisch.docx
Stand: 13.01.16
Seite 10 von 16
3.5. Setting Off-Mode 1 (with test cable)
(Upper and lower end position about torque detection) - Automatic setting
Step No.
Operation
Note
Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.
3.6. Setting Off-Mode 1 (with micro switch and switch)
(Upper and lower end position about torque detection) - Automatic setting
Step No.
Operation
Note
Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.