2. Setting Instructions - Type: S, GS, SI, SIG, R, G
The drive has 2 different switching modes, the selection takes place automatically via the setting.
2.1. Overview Off-Mode 1 –
Only suitable for type S
Upper end position about torque detection
(shutter moves against the stop) / End position
down after putting on the armor guided tour through
the system detects that the winding shaft.
An end position readjustment, caused by elongation or
Cord elongation, automatically carried out from the up-
per end position.
2.2. Overview Off-Mode 2 - For all types with box on bottom
Upper end position about torque detection
(shutter moves against the stop) / set end position
bottom.
An end position readjustment, caused by elongation or
Cord elongation, automatically carried out from the up-
per end position.
Note
After the installation of the drive the spring shaft can be loaded via the programming button and the cord can be put in the cor-
rect position.
-
Please note the separate instructions
-
Upon delivery, unnecessary
If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be set into learn-
ing mode again.
Important!
Adhere to the sequence, first the upper and then the lower float stop has to be
teached.