Safety instructions

Prior to installation and commissioning of this device, please

read completely through this manual. Please observe in partic-

ular the regulations and operating instructions  containing the

hazard symbols and safety signs. Non-observance can result

both in damage to the device and personal injuries.

If, after reading through the manual, you have further questions,

please contact the manufacturer or the local sales office.

General information

SCHAKO shall not give any warranty for damage resulting from:

Warranty

The device warranty will be for two years starting from the

handover date and shall apply to all production faults. Electric

components are excluded from the device warranty. However,

they are covered by the corresponding warranty of the relevant

manufacturer

Also excluded from the warranty is damage to the device unit

caused by components that are not part of the device itself.

The warranty only covers the return and replacement of defec-

tive materials.

Recycling

- The inspection, installation, hydraulic connection and com-

missioning of the device must be carried out by qualified

skilled personnel only in compliance with the current regula-

tions.

- Electric and hydraulic connections and their correct function-

ing are the responsibility of the installer.

- Do not change any control or safety elements without prior

approval by the manufacturer or the local sales office.

- Improper use caused by ignoring the instructions given in

this manual

- Non-observance of the operating conditions of the device.
- Installation and maintenance by personnel without proper

qualification.

- Improper use of the device or operation under conditions not

conforming to the manual.

- Use of spare parts that are not original spare parts.

It is recommended recycling the components of

the device at the end of the device service life as

completely as possible or use them for a different

purpose. Components that cannot be recycled

must be properly disposed of by an authorized dis-

posal company in accordance with current legal

regulations.

It is recommended keeping this manual at a safe lo-

cation after installation and use it for future mainte-

nance activities.

Hazard warning

Important information

Safety information

Recycling

Summary of Contents for DISA-B

Page 1: ...Ferdinand Schad KG Steigstra e 25 27 D 78600 Kolbingen Telephone 49 0 74 63 980 0 Fax 49 0 74 63 980 200 info schako de www schako de Installation Mounting and Maintenance DISA B DISA B...

Page 2: ...tion of the delivered model 4 Function 4 Installation and commissioning 5 Operating conditions 5 Material reception 5 Transport lifting and handling 5 Storage 5 Installation 6 Mounting 6 Hydraulic con...

Page 3: ...acement of defec tive materials Recycling The inspection installation hydraulic connection and com missioning of the device must be carried out by qualified skilled personnel only in compliance with t...

Page 4: ...nd heating or optionally 2 pipe system cooling or heating The registers consist of cop per pipes 12 mm in thickness aluminium ribs a steel frame and a manual ventilation and drainage system Grid 3 Lou...

Page 5: ...150 Total length 1150 mm M Position of primary air plenum box central WS1 Water connection left AS1 Number of connection pipes 1 connection pipe arranged cen 123 Diameter of the connection pipes 123 m...

Page 6: ...ory authori ties and adjusted in height later on Hydraulic connections Make sure that places that are intended as openings for air admission and air discharge are free of pipes electric cables crossbe...

Page 7: ...rature controls The temperature controls are mounted in accordance with the selected model This is why the instructions enclosed with each model must be followed However in order to achieve optimum me...

Page 8: ...e access for carrying out the maintenance activi ties has been provided Use the on site ventilation device to ensure that no air re mains in the register and the circuit The connecting and fastening e...

Page 9: ...y may impair or damage the materials of theMainte nance DISA B galvanised steel aluminium and copper and the surface coatings paints and anodised surfaces If there are larger differences in distance b...

Page 10: ...ressure transducer must be closed again The values read on the meter and the following formula can be used to to determine the volumetric flow V l s Primary air flow Ps Pa Static pressure The K value...

Page 11: ...draulic system Ventilation of the hydraulic system Please inform the installer Installed unfavourably or malfunctions at the temperature control or sensor Install thermostat in a different place Clogg...

Reviews: