background image

DIN EN 55011:2009 + A1:2010 / Group 1 / Class A

Industrial, scientific and medical equipment - Radio-
frequency disturbance characteristics - Limits and 
methods of measurement

Class B limits (devices for usage in domestic establish-
ments) are met with an additional ferrite attached to the 
USB connector cable (camera side).

The product complies with the following standards and 
directives:

2014/30/EU

EMC Directive

DIN EN 61326-1:2013

Electrical equipment for measurement, control and 
laboratory use – EMC requirements

Part 1: General requirements

CE-Conformity

 

Instruction Manual

 SK1024U3HU

 

 

  

shar

ed_CE-Conformity_W

arranty_ML.indd

29

Instruction Manual SK1024U3HU    © 2019-07 E

Copyright  ©

Unless explicitly allowed, distribution, sale or use of this document or its contents, for purposes other than 
those intended, is forbidden. Repeated transgressions will lead to prosecution and demands for compensation.

All rights of patent protection and registration or copyright of a product or its design lie with Schäfter+Kirchhoff. 
Schäfter+Kirchhoff GmbH and the Schäfter+Kirchhoff logo are registered trademarks.

We reserve the right to improve or change specifications so that the system description and depictions in the 
Instruction Manual may differ in detail from the system actually supplied. The Instruction Manual is not covered 
by an update service.

Date of document publication: 15.07.2019

Schäfter+Kirchhoff GmbH 

 

Tel.:  +49 40 853 997-0 

Kieler Straße 212 

 

 

Fax:  +49 40 853 997-79 

22525 Hamburg 

 

 

Email:  [email protected] 

Germany    Internet: 

 

www.SuKHamburg.com

This manual has been prepared and reviewed as carefully 
as possible but no warranty is given or implied for any 
errors of fact or in interpretation that may arise. If an error 
is suspected then the reader is kindly requested to inform 
us for appropriate action.

The circuits, descriptions and tables may be subject to 
and are not meant to infringe upon the rights of a third 
party and are provided for informational purposes only.

The technical descriptions are general in nature and 
apply only to an assembly group. A particular feature 
set, as well as its suitability for a particular purpose, is 
not guaranteed.

Each product is subjected to a quality control process. 
If a failure should occur then please contact the supplier 
or  Schäfter + Kirchhoff  immediately.

The warranty period covers the 24 months from the 
delivery date. After the warranty has expired, the manufac-
turer guarantees an additional 6 months warranty for all 
repaired or substituted product components.

Warranty does not apply to any damage resulting from 
misuse, inappropriate modification or neglect. The 
warranty also expires if the product is opened. The 
manufacturer is not liable for consequential damage.

If a failure occurs during the warranty period then the 
product will be replaced, calibrated or repaired without 
further charge. Freight costs must be paid by the sender. 
The manufacturer reserves the right to exchange compo-
nents of the product instead of making a repair. If the 
failure results from misuse or neglect then the user 
must pay for the repair. A cost estimate can be provided 
beforehand.

Warranty

Summary of Contents for SK1024U3HU

Page 1: ...cy up to 13 88 kHz Instruction Manual SK1024U3HU 3 2 4 1 Sample Configuration 1 CCD line scan camera SK1024U3HU mounted with 2 Mounting bracket SK5105 3 Clamping claws SK5102 4 Video CCTV objectiv 1 0...

Page 2: ...directly into the light beam Mechanics Warning Ensure that the motion device and the scan way is free to move and that no obstacles are in the way Do not place any part of the body in the way of movi...

Page 3: ...LineScan Start up 8 Camera Setup 8 Initial Function Test 9 3 Camera Control and Performing a Scan 11 3 1 Software SkLineScan 11 Function Overview SkLineScan Toolbar 11 Visualization of the Sensor Outp...

Page 4: ...the SK91USB3 WIN CD then the camera can be parameterized The parameters such as integration time synchronization mode or shading correction are permanently stored in the camera even after a power down...

Page 5: ...ideo signal monochrome 8 12 Bit digital Interface USB 3 0 Voltage USB 350 mA Power consumption 1 8 W Casing 65 mm x 52 4 mm Case type AT1 Objective mount C Mount Flange focal length 17 53mm Weight 0 2...

Page 6: ...ordered as a kit the components are pre assembled and shipped as one unit Keep the protective cap on the lens until the mechanical installation is finished If you must expose the sensor or lens surfac...

Page 7: ...of synchronized operation the external trigger signal s must be wired to socket 2 A frame synchronization signal and two separate line synchronization signals can be handled The various trigger modes...

Page 8: ...ownloaded zip file to a temporary folder Alternatively if your installation medium is a CD insert the disk to the drive The autostart function may launch the setup program automatically from CD Otherw...

Page 9: ...n Software_USB3 indd Instruction Manual SK1024U3HU 2019 07 E Initial Function Test Quit the SkLineScan startup dialog box Select OK in the SkLineScan start up dialog The Signal Window showing the curr...

Page 10: ...Instruction Manual SK1024U3HU shared_blank indd 10 Instruction Manual SK1024U3HU 2019 07 E...

Page 11: ...The SkLineScan program recog nizes the connected line scan cameras automatically The identified cameras are shown in the start up dialog A If the SK1024U3HU camera is identified correctly confirm with...

Page 12: ...sor Platzhalter f r Grafiken in anderen Ebenen Zoom Function With a high number of sensor pixels details are lost due to the limited number of display pixels With the zoom function you select a part o...

Page 13: ...es the effective focussing of the line scan camera system even for two dimensional measurement tasks For determining the correct focus the edge steepness at dark bright transi tions and the modulation...

Page 14: ...ther Offset sliders A slight signal noise should be visible in the zero baseline 2 Gain Illuminate the sensor with a slight overexposure in order to identify the maximum clipping Use the Gain slider 1...

Page 15: ...the scale range Minimum in intensity values lower than Minimum will not be changed A typical appropriate value is 10 of the full intensity range i e 26 10 255 for an 8 bit intensity scale Maximum in t...

Page 16: ...tting optimum signal sensitivity is achieved and overexposure or even blooming is avoided Open the Camera Control dialog Menu Edit Operation Parameters or F4 The integration time can be set by two ver...

Page 17: ...ch fter Kirchhoff contain easy to use functions for this purpose If the object speed is variable or the accuracy requirements are high external synchronization is required The various synchronization...

Page 18: ...exposure are controlled internally by the camera and are not affected by the trigger pulse The exposure time is programmable The line frequency is determined by the frequency of the trigger signal Li...

Page 19: ...r dividers Enter the division ratio in the Divider field Select the Frame Sync check box to activate frame synchronization In the Delay field enter the delay time in milliseconds Clock Select AD Conve...

Page 20: ...oduct information can be read from the camera using the request commands All set and request commands are listed in the tables below The commands are entered in the Input field in the Camera Control s...

Page 21: ...T decoupling of line clock frequency and exposure time RDXT CR disable DXT decoupling of line clock frequency and exposure time SLUT CR enable LUT RLUT CR disable LUT SNES CR enable NES no EEPROM save...

Page 22: ...x x Sync 4x Enable x x 1 x x x x x Sync up Enable down disable x 0 x x x x x x Sync up down Enable x 1 x x x x x x Sync Ctrl Disable SyC3 SyC6 without function 0 x x x x x x x Sync Control Enable 1 x...

Page 23: ...xxx b C 1 Trigger on 4 edges of SyncA and SyncB direction detection off hysteresis 0 Sync Control Register 11100xxx b D 1 Trigger on 4 edges of SyncA and SyncB direction detection off hysteresis 4 Syn...

Page 24: ...amatsu Type S11637 1024Q 1024 pixels Data source Hamamatsu CMOS linear image sensor series S11637 Cat No KMPD1131E02 Aug 2016 DN a Features Electronic shutter function Gain switching function Pixel si...

Page 25: ...Instruction Manual SK1024U3HU shared_Sensor_S11637 series indd 25 Instruction Manual SK1024U3HU 2019 07 E Overall structure c Spectral Response typical example d Spectral Transmittance Characteristics...

Page 26: ...or Information Instruction Manual SK1024U3HU shared_Sensor_S11637 series indd 26 Instruction Manual SK1024U3HU 2019 07 E e Electrical and Optical Characteristics Ta 25 C Vdd 5V V CLK V ST 5V f CLK 10...

Page 27: ...ermines the minimum exposure period Line frequency line scan frequency is the reciprocal value of the exposure period The maximum line frequency is a key criterion for line scan sensors as this is the...

Page 28: ...compatible with each other For more accurate requirements or with a variable object velocity external synchronization is necessary Synchronization of the Imaging Procedure and the Object Scan Velocity...

Page 29: ...2525 Hamburg Email info SuKHamburg de Germany Internet www SuKHamburg com This manual has been prepared and reviewed as carefully as possible but no warranty is given or implied for any errors of fact...

Page 30: ...B 3 0 plug type A also fits into a USB 2 0 type A socket SK9020 x Order Code 1 1m cable length 3 3m cable length standard USB 3 0 active extension cable USB3 EXT AA10 External power supply 5VDC length...

Reviews: