Appendix
Page 8-4
BASCC BC - 02.08 - V01
8.3
Serials Plates of Steam Generator and Instant Heater
Type DA
HW
HW
Excess operating pressure
2.5 bar
2.5 bar
2.5 bar
Maximum operating. pressure p max
12 bar
12 bar
12 bar
Test excess pressure
24 bar
24 bar
24 bar
Maximum op. temperature
T max
192 ºC
192 ºC
192 ºC
Minimum op. temperature
T min
10 ºC
10 ºC
10 ºC
Operating temperature
140 ºC
95 ºC
95 ºC
Water capacity
Vol.
0.8 l
0.8 l
1.2 l
Constr.
year:
20.. 20.. 20..
Manufacture number
DA.....
HW.....
HW.....
Voltage
U
230 VAC.
230 VAC.
230 VAC.
Frequency
f
50/60 Hz
50/60 Hz
50/60 Hz
Capacity (Watts)
P
3000 W
3000 W
2x3000 W
Design and testing according to SVTI and TÜV regulations.
8.4
Environmental Aspects
Packaging:
The machines are delivered in recyclable cardboard boxes on reusable pallets.
Spare parts:
Parts exchanged during a service are reconditioned as far as possible and used
again.
Cleaning agent
Environmental protection!
If no recycling is possible, cleaning agents and their packaging must be disposed of in
line with local laws and regulations in accordance with the "HEALTH AND SAFETY
DATA SHEET."
Energy consumption
The energy consumption corresponds to the technical state of the art at the time the
machine was developed.
Disposal:
Environmental protection!
The machines must be disposed off correctly and in line with local laws and
regulations.