Utility Hook-Up Requirements
Utility Hook-Up Requirements
G
Y
X
POWER, WATER SUPPLY, AND ACCESS REQUIREMENTS
The receptacle, water
shut-off valve and drain
pipe must be within 3 feet
(36
"
) of the center of the
location (footprint) of the
machine.
Ideal under counter space
for softener: 30
"
(minimum
requirement: 26
"
).
• Receptacle type: NEMA L6-20R
• 3 Prong twist-lock
• Breaker panel: 20 Amp dedicated 220V
single phase circuit
• Actual maximum load: 16 Amps
• Access hole with collar (no sharp edges)
• Located centrally under machine for water
and drain hose
• Diameter: Minimum 3
"
• Water shut-off valve with 3/8
"
compression
fitting
• Back flow preventer in accordance with
local requirements
•
Drain pipe to floor drain
• Copper or PVC in accordance with local
health codes and regulations
• Diameter: 1.5
"
or larger
Notes: Access hole is only required if any of the utility hook-ups are located under the counter.
3” Diameter Access
Hole Located Rear
Center of Machine
1” Diameter
Drain Hose
1 1/2” Diameter
Drain Pipe to Floor
Drain
15 1/2”
4” Clearance
3” Clearance
The receptacle (NEMA L6-20R),
water filter and scale inhibitor
can be located either under the
counter or top of counter behind
the machine.
4”
Water Filter
17"
22"
2” Side Clearance
3” Rear Clearance
33"
8” Top
Clearance
Summary of Contents for 040381-00051EUS
Page 16: ...16 User Manual 03 2021 v04...
Page 22: ...www schaererusa com Maintenance Hopper Cleaning 22 User Manual 03 2021 v04...
Page 26: ...26 User Manual 03 2021 v04...
Page 29: ...29 User Manual 03 2021 v04 www schaererusa com Notes Notes...
Page 30: ...30 User Manual 03 2021 v04 www schaererusa com Notes Notes...