- 23 -
User Manual | 03.2021 | v04
www.schaererusa.com
Error Messages
Error Messages
Display Message
Cause
Remedy
Grounds container missing
• The grounds container was removed
(cleaning program, emptying, etc.)
• The limit switch is defective.
► Insert grounds container.
If the message persists, call for service.
Empty grounds container
• The grounds container is full.
► Empty the grounds container and reinsert it.
Cleaning program
• Appears when a programmed count of
beverages has been dispensed without the
machine being cleaned.
► The machine must be cleaned.
Refer to page 17-20 for daily cleaning procedures.
Grinder left/right no beans
• Appears when the bean hopper on the left-
or right is empty or when a coffee bean has
become stuck.
Beverage output is blocked!
► Refill the bean hopper with coffee beans (max.
1000g.) and confirm.
► Check bean slides (oval hoppers). Refer to page
22.
► Check bean release (standard hoppers). Refer to
page 21.
► If jammed, use the stem of the cleaning brush
to “stir” the coffee beans around and unclog the
grinder. Then press confirm.
Grinder left/right blocked
• An object (such as a stone) has become
jammed in the left or right grinder.
Beverage output is blocked!
► Check grinder for blockage. Remove bean
hoppers and vacuum remaining beans if
necessary. Then press confirm.
If the message persists, call for service.
Heating coffee water/hot water/
steam
• The temperature is 10° C below the
programmed temperature.
► Wait until the temperature has been reached.
If the message persists, call for service.
Service request
• The programmed number of beverages
(cups/month) has been reached. Service is
required.
► Call for service.
Grinder left/right overloaded
• Left/right grinder is overloaded.
• Grinder left/right blocked.
► Check grinder for blockage. Remove bean
hoppers and remaining beans with vacuum if
necessary. Then press confirm.
If the message persists, call for service.
Grinder current fault
• PC board issue.
• Electronics issue.
► Call for service.
Brewing unit current fault
• PC board issue.
• Electronics issue.
► Call for service.
Over current brew motor
• Brewing unit is drawing too much current
(over 4A).
• Brewing unit is jammed.
► Call for service.
Water flow error
• No water connection.
• Pump problem. (pump pressure < 5bar)
• Brewer is blocked.
• Water system is blocked.
• Grind level is too fine.
• PC board and flow meter are improperly
connected.
• Electrical problem (e.g. PC board).
► Check water supply.
If the message persists, call for service.
Summary of Contents for 040381-00051EUS
Page 16: ...16 User Manual 03 2021 v04...
Page 22: ...www schaererusa com Maintenance Hopper Cleaning 22 User Manual 03 2021 v04...
Page 26: ...26 User Manual 03 2021 v04...
Page 29: ...29 User Manual 03 2021 v04 www schaererusa com Notes Notes...
Page 30: ...30 User Manual 03 2021 v04 www schaererusa com Notes Notes...