10
Schaeffler Technologies
■
The electronic systems switch off automatically if the
ambient temperature rises above 70ºC.
■
When heating in temperature mode, the heater switches off
if no 1°C temperature increase is measured during a time
pre-set by the manufacturer.
■
The coil of the heater is equipped with a temperature
monitor. If the coil becomes too hot, the heating process is
switched off entirely.
■
Models with a swivel arm are equipped with a safety
positioning cam.
An induction heater operates by means of a magnetic field.
At a distance of 1 metre, the magnetic field has been reduced to
such an extent that it is below the applicable standard of 0.5mT.
2.4 Safety provisions
WARNING!
Danger of death for persons with artificial
heart valves made from metal, hazard of
severe burns due to heating of implants by the
electromagnetic field, see chatper 2.2.
Ensure that persons with a ferromagnetic
implant remain outside the hazard area of the
heating device. Erect barriers and attach clearly
visible warning signs, Figure 1.
1 m
2
1
3
1. Hazard area, 1m
2. Barrier
3. Flat work surface capable
of supporting load
Figure 1