Schaeffler Technologies
BA 35
17
Troubleshooting and
rectification
This section covers errors that may occur and the associated
remedial measures.
Error messages
Error message
Cause of error
Remedy
Grease signal
does not change
The sensor head is not
in contact with the grease
Immerse the sensor head
in the grease to a greater
depth
The sensor is too far
from the changed grease
Deposits on the sapphire
disc
Clean the sapphire disc
using a microfibre cloth
No signal
The sensor head
is not inserted
Insert the sensor head
in the rolling bearing
The sensor head
is defective
Replace the sensor head
Cable breakage
(analogue signal
⬍
4 mA)
GreaseCheck is being
operated outside
the intended range
Replace the signal cable
Power supply is
present but CAN
communication
with the sensor is
not possible
Terminal resistance
is set incorrectly
Set the 120 ohm terminal
resistance for the CAN bus,
see Mounting of evaluation
unit
LED on
controller shows
continuously red
The firmware is caught
in bootloader mode
Disconnect the power to
the sensor and restart
Summary of Contents for GreaseCheck
Page 1: ...Schaeffler GreaseCheck User manual...
Page 2: ......