SCARAB M6 SWEEPER KIT
Amdt.1 - 03 November 2009
Operator’s Manual
6
DESCRIPTION OF SWEEPING CONTROLS
Fig. 1 Sweeper Control Panel Layout
BEACONS
AUXILIARY ENGINE STOP
AUXILIARY ENGINE
PANEL ON/STAND-BY
LEFT HAND
LEFT NOZZLE
WIDESWEEP
LEFT SIDE WATER
RIGHT HAND
RIGHT NOZZLE
RIGHT SIDE WATER
LEFT SIDE
RIGHT SIDE
HIGH-PRESSURE WATER PUMP •
LIQUID CRYSTAL DISPLAY
AMBIENT LIGHT
START
SENSOR
(LCD SCREEN)
WORK LIGHTS
RAISE/LOWER
SIDE-BRUSH
WORK LIGHTS
SIDE-BRUSH
RAISE/LOWER
SUCTION FAN
WIDESWEEP WATER
• indicates optional equipment
SIDE BRUSH
NOZZLE TILT (MOMENTARY)
When in Sweep Mode:
UPPER LINE = ENGINE SPEED
LOWER LINE = WATER TEMPERATURE / WARNINGS
MANUAL
PRE-HEATERS
SWING IN/OUT
NOZZLE TILT (LOCKING)
SWEEP MASTER
SWITCH
SIDE BRUSH DOWN PRESSURE •
OPTION
THE CANbus SYSTEM
The CANbus Sweeper Control System comprises a control panel and three
control nodes. The system controls and monitors all sweeper functions. The
main panel contains a CPU which holds all the program information and
also logs operating system errors. This greatly simplifies the process of
identifying and curing operating faults. The control nodes are located
adjacent to the sub-systems they control. The CANbus control panels use
touch switches; these are covered by a flexible overlay to identify their
functions. The various types of switch function are grouped in two ways.