Introduction

The 9452 and 9453 are fully programmable 4 zone control units designed to
meet the requirements of both domestic and small commercial installations.

The basic 9452 system comprises a main control panel complete with built-in
keypad, while the 9453 system comprises a blank end station and one
remote keypad. The 9452 control unit and 9453 end station both house the
system electronics, power supply, battery and remote signalling device (if
fitted). A numeric keypad and row of indicators (LEDs) are provided only on
the 9452 control unit, from which the user and installer perform the system
operation.

Remote keypads provide the user with the facility to set and unset the system
from strategic locations within the premises and allow the installer to pro-
gramme the system. Up to TWO remote keypads may be connected to the
9452/3. A numeric keypad and row of indicators (LEDs) are also provided on
the keypads to perform the system operation. The keypads also have an
optional key press PA facility, if required.

Technical Specification

Zones

Four plus PA, Entry/Exit and global tamper.

Display

LED.

Keypads

One built-in (9452 only) plus up to two remote keypads

(9425).

Expansion

None.

BS 4737

Full Spec.

Log

15 events.

Panel Siren

Yes.

Extension Spkr

9040, 2 max if Internal Speaker is disconnected.

Battery

1.9Ah.

12 Volt Power

Quiescent Panel 70mA.
9425 RKP = 40mA.

12 V Aux Output

350mA.

Dimensions

Panel: h x w x d 163 x 257 x 72mm.
RKP: h x w x d 115 x 115 x 28mm.

Weight

Panel 1.2Kg.

Comms Output

PA, Intruder, Open/Close.

Input

Line fault.

Outputs

SAB/SCB, Strobe, Prog O/P (PIR set latch or SD reset).

9452/3

Summary of Contents for 9452

Page 1: ...496330 Issue 1 1 of 10 9452 9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4 Channel Minicom ...

Page 2: ...stem from strategic locations within the premises and allow the installer to pro gramme the system Up to TWO remote keypads may be connected to the 9452 3 A numeric keypad and row of indicators LEDs are also provided on the keypads to perform the system operation The keypads also have an optional key press PA facility if required Technical Specification Zones Four plus PA Entry Exit and global tam...

Page 3: ...5 12V Brown 12V Pin 6 0V Orange 0V Notes 1 Pins 1 3 and 4 are removal of positive in alarm to trigger 2 Pin 2 is a 12V ve input for Line Fault 3 If a communicator is fitted and has an output for line fault connecting a ve to the Line Monitor Input will reduce any programmed bell delay to zero and give a visual indication on the panel LED LF 4 If a communicator is not fitted remove the communicator...

Page 4: ...d The control panel or end station lid switch should be defeated or closed and NO power connections to detectors sounders or battery should be made at this stage Note If connections to the bell and AUX power are made when the system is powered up damage to the main pcb may occur 1 Apply mains to the control panel or end station The green Power and Day LED will illuminate and the internal sounder w...

Page 5: ...ted in this section as follows 1 Enter the command number 2 Enter one or more digits to give the new program 3 Press ENTER The panel will give a double bleep to show that it has accepted the command If you enter the command incorrectly the panel gives a single tone Default Settings When delivered from the factory the panel is programmed as follows Zone 1 Entry Route Part Set zone 01 36 Zone 2 Norm...

Page 6: ...stem Reset 31 0 Customer Reset y 1 Engineer Reset Abort facility 32 0 Disabled y 1 Enabled Keypad PA 33 0 Disabled y 1 Enabled System status 34 0 LEDs ON when set and part set 1 LEDs OFF when set and part set y Exit Mode 35 0 Timed or Terminated y 1 Final Door Set Rearm 40 0 Never y 1 Once 2 Twice 3 Three times 4 Always External sounder delay 41 0 Nil y 1 1 5 mins 2 3 mins 3 5 mins 4 10 mins 5 15 ...

Page 7: ...to quit log 15 events max External Sounder 91 ENTER to stop test Strobe 92 ENTER to stop test Internal Sounder 93 ENTER to stop test Test keypad LEDs 94 ENTER to stop test Output 1 95 ENTER to stop test Walk Test 97 ENTER to stop test Load Factory Defaults 98 Leave Engineering Mode 99 Refresh NVM System Memory Chip The 9452 3 control panels have a Non Volatile Memory chip which retains all program...

Page 8: ...Enter Programming Mode 1 Press 0 then Enter 2 Key in the Engineer Access Code The Fault and Service LEDs flash and the internal sounder starts bleeping 3 Open the control panel or end station lid The internal sounder stops bleeping and the Service LED glows stead ily The system is now in programming mode To Leave Programming Mode 1 Close the panel or end station lid 2 Key in 99 Fault Finding Under...

Page 9: ...496330 Issue 1 9 of 10 9452 3 Fault Finding ...

Page 10: ... zones as required Omit 24 hr zone OMIT ENTER User code zone number zone number for other zones as required Change User code 4 ENTER Old code Old code the system beeps twice New code the system beeps twice Read Log 5 ENTER User code 1 to read earlier events 3 to read later events ENTER to leave the log Chime On Off 7 ENTER User code Bell Test 8 ENTER User code Walk Test 9 ENTER User code ENTER to ...

Reviews: