6 of 10
496330 Issue 1
To change
Key in:
Followed by + ENTER
Default
Entry/exit zone options
07 0 = Reset to none
5 = Chime
6 = Part set zone
Programmable Output
11 18 = PIR set latch
y
29 = Shock sensor reset
Engineer Access
20 Any 4 digit code
7890
Bell output type
21 0 = SAB
y
1 = SCB
Internal sounder
22 1 = Follows strobe
y
0 = Follows bell
PA
30 0 = Audible Alarm
y
1 = Silent Alarm
System Reset
31 0 = Customer Reset
y
1 = Engineer Reset
Abort facility
32 0 = Disabled
y
1 = Enabled
Keypad PA
33 0 = Disabled
y
1 = Enabled
System status
34 0 = LEDs ON when set and part set
1 = LEDs OFF when set and part set.
y
Exit Mode
35 0 = Timed or Terminated
y
1 = Final Door Set
Rearm
40 0 = Never
y
1 = Once
2 = Twice
3 = Three times
4 = Always
External sounder delay
41 0 = Nil
y
1 = 1.5 mins
2 = 3 mins
3 = 5 mins
4 = 10 mins
5 = 15 mins
6 = 20 mins
7 = No duration
Ext. sounder duration
42 0 = Nil
1 = 1.5 mins
2 = 3 mins
y
3 = 5 mins
4 = 10 mins
5 = 15 mins
6 = 20 mins
7 = No duration
Engineering Program Commands