![Scantronic 9448+ Installation And Programming Manual Download Page 29](http://html.mh-extra.com/html/scantronic/9448/9448_installation-and-programming-manual_1207049029.webp)
496236 Issue 4
27
Programming Example
To program the installation example given in Section 2 some changes need to
be made to the factory default settings. For the example we will assume that
the:
Entry time must be 30 seconds
Exit time must be 45 seconds.
Entry Exit zone and back door should chime.
System should rearm three times.
Key in:
Result
1. 0 + ENTER + 7890
The panel enters programming mode and
all LEDs (except Power) flash in unison.
2. 10 + ENTER + 6 + ENTER
Zone 6 is by passed during Part Set.
3. 11 + ENTER + 72 + ENTER Entry exit zone and zone 2 are chime
zones.
4. 40 + ENTER + 4 + ENTER
Rearm three times.
5. 43 + ENTER + 3 + ENTER
Entry time 30 seconds.
6. 44 + ENTER + 4 + ENTER
Exit time 45 seconds.
7. 52 + ENTER + 1 + ENTER
Zone 1 is Entry/Exit Zone in Part Set.
8. 99 + ENTER
Leave programming mode.
If you wish to make zone 6 a PA zone, then you could add the step:
7a. 50 + ENTER + 1 + ENTER
Zone 6 is a PA zone.
Summary of Contents for 9448+