![Scantronic 9448+ Installation And Programming Manual Download Page 26](http://html.mh-extra.com/html/scantronic/9448/9448_installation-and-programming-manual_1207049026.webp)
24
496236 Issue 4
The panel beeps twice to show that it has accepted the command. All the
LEDs flash, and the panel is ready for the next command.
The panel
gives a single error tone if you enter an incorrect command.
Re-enter the correct command.
3.
Key in "99 ENTER" to leave programming mode when you have finished.
You will then be in user mode.
Engineer Program Command List
To change:
Key-in:
followed by:
Notes
Zones omitted in
10
ENTER
zone n..n
ENTER
LEDs ON for zones
Part Set*
omitted (see note 1)
Chime
11
ENTER
zone n..n
ENTER
LEDs ON for chime
(EE zone = zone 7)
Zones Not Used
15
ENTER
zone n..n
ENTER
LEDs OFF for zone
not used (see note 2)
Engineer Code
20
ENTER
new code
ENTER
4 digits
User Code 1
21
ENTER
new code
ENTER
4 digits (see note 3)
User Code 2
22
ENTER
new code
ENTER
4 digits (see notes 3 & 4)
Silent Part set
35
ENTER
0
ENTER
Audible
1
ENTER
Silent
Zone 2 Entry
36
ENTER
0
ENTER
Normal Alarm
Route
1
ENTER
Entry Route
Auto Re-Arm
40
ENTER
1
ENTER
Never rearm
2
ENTER
Rearm once
3
ENTER
Rearm twice
4
ENTER
Rearm three times
Bell Time
42
ENTER
1
ENTER
90 seconds
2
ENTER
3 minutes
3
ENTER
10 minutes
4
ENTER
20 minutes
Entry time
43
ENTER 1
ENTER
10 seconds
2
ENTER
20 seconds
3
ENTER
30 seconds
4
ENTER
45 seconds
5
ENTER
1 minute
Exit time
44
ENTER
1
ENTER
10 seconds
2
ENTER
20 seconds
3
ENTER
30 seconds
4
ENTER
45 seconds
5
ENTER
1 minute
4. Programming