![Scantronic 9448+ Installation And Programming Manual Download Page 17](http://html.mh-extra.com/html/scantronic/9448/9448_installation-and-programming-manual_1207049017.webp)
496236 Issue 4
15
(b) Separate the back plate from the cover. Mount the required module and
the bell to the back plate. Fix the strobe to the cover using suitable
fixings. Fix back plate to the wall using not less than 40mm x 8 screws. If
available fix using 10mm Rawl Bolts.
Wiring the Control Panel
Cable Entries
The back of the control panel case provides a 30mm round cable entry at the
left hand side and a trunking knockout at the top left.
Mains Connection
The panel must be permanently connected to an unswitched spur outlet fitted
with a 1 Amp fuse. Connect the mains supply to the control panel using the 3-
way terminal block located in the panel back. Note that the panel does not
have an internal mains fuse. All electrical connections should be carried out
by a qualified electrician and must comply with the current IEEE Wiring
Regulations: 16 Edition, Appendix 5 - Standard Circuit Arrangement.
Figure 9. Mains Connection
Caution: Do not apply mains power at this point.
Battery Connection
The control panel must be fitted with a 2.1AH maximum rechargeable battery.
Caution: Do not apply battery power at this point.
Connecting a 9427 Remote Keypad
Figure 10 shows the connections for a 9427 Keypad.
3. Installation
Summary of Contents for 9448+
Page 1: ......