3.3.6
Micro-speed control
This return spring switch can be used to reduce the operating speed in five (5) steps
from 100% to 60%, 50%, 40%, 30% and 20% speed by limiting the hydraulic
steering. The regulation of the function's speed is still made over the entire lever
stroke and with retained resolution.
•
With impulses from the spring loaded toggle switch to the left, towards the turtle
, speed reduction can be produced from 100% to 60%, 50%, 40%, 30%
and 20% steering.
•
Movement of the switch to the right, towards the rabbit
, will produce 100%
steering once again.
•
For safety reasons, a return to 100% steering can only be made if all manoeuvre
levers are in their zero positions.
•
When the green LED is blinking, the Micro-speed function is activated. The
number of blinks indicates the operating speed as defined in the table below. If
the stop function is pressed on the controller unit, the controller unit will start
from the last chosen speed.
Green LED
Indication
not lit
0 to 100 % speed (normal speed)
1 blink every third second
0 to 60 % speed
2 blink every third second
0 to 50 % speed
3 blink every third second
0 to 40 % speed
4 blink every third second
0 to 30 % speed
5 blink every third second
0 to 20 % speed
11/37