INSTALLATION GUIDE 

 

1. Take unit out of box (following the instructions in the previous section) and place on a 

strong table/base, or the trolley if provided, capable of supporting up to 200 kgs. Take 
extreme care when lifting as the unit is very heavy (160 kgs/352 lbs). Use a lifting trolley 
or fork lift truck. Ensure that there is unrestricted access to the inspection chamber door.  
Ensure that the door is fully closed. 

 
2. Connect monitor to unit by means of the ‘D’ connector and power cables supplied 
 
3. Connect the trackball and place on a suitable surface. (Can be hand held during operation) 

 

4. Plug unit into the mains supply after checking voltage of machine matches local voltage 
 
5. Ensure that the door is fully closed and insert the key into the key switch on the front 

control panel and turn it clockwise to switch on the unit. The green 

SYSTEM READY 

light should illuminate to indicate the interlocks have been operated and that the equipment 
is ready for use. 

 

6 Perform interlock check by doing the following: 

Activate the red 

X-RAY ON 

button on the front control panel.  Observe that all X-ray 

lights illuminate and that they remain illuminated.  Slowly open the loading door and verify 
that the 

X-RAY ON 

and warning indicators switch off 

as soon as the door is opened. 

 
7. Check image quality by placing a sample package into the centre of the inspection cabinet. 

 

8. Using the Trackball check that the left hand switch rotates through the zoom function and 

that the right hand switch rotates through the six image formats. 

 

IMPORTANT 

Upon installation and after any relocation a critical examination report should be carried by qualified staff 

with the appropriate radiation survey equipment using copy of the report found on page 23 for record 

purposes. 

If all controls function properly and the radiation tests show the equipment to be safe then the SCANMAX 
is ready for operation 
 

 

WARNING 

 

THIS EQUIPMENT PRODUCES IONISING RADIATION WHEN ENERGISED AND SHOULD BE 

OPERATED ONLY BY TRAINED PERSONNEL 

 
 

 

Summary of Contents for SCANMAX 25 C

Page 1: ...C DESK TOP CABINET SECURITY X RAY SCREENING SYSTEM FITTED WITH COLOUR CAMERA 230V SCANNA MSC LIMITED 104 New Bond Street Telephone Facsimile London Nat 0207 355 3555 Nat 0207 355 3556 W1Y 9LG Int 00 4...

Page 2: ...Date Amendment No Page No Details...

Page 3: ...shielding the user should be aware that the useful beam can constitute a distinct hazard if not employed in strict accordance with instructions contemplated to provide maximum safety for the operator...

Page 4: ...NG INSTRUCTIONS 13 X RAY SCREENING PROCEDURES 14 MAINTENANCE 16 Line grounding and regulation 16 Fuse replacement 16 X ray Generator and Controller replacement 17 Door Adjustment 18 Camera adjustment...

Page 5: ...delivered items not passing through the central mailroom The SCANMAX 25 is completely self contained and can be put into operation immediately and can examine the contents of a parcel 40 x 50 cm 16 x...

Page 6: ...y notify the carrier at your location UNPACKING THE SCANMAX 25 To remove the SCANMAX from the shipping crate perform the following 1 Undo the binding and open the box with the help of a large screwdri...

Page 7: ...d replace the screws into the unit Do not operate the unit with the handles fitted Do not attempt to open the door on the Scanmax 20 with the rear handle fitted WARNING When lifting the unit extreme c...

Page 8: ...ll be set at 230V unless otherwise instructed and should therefore only be operated from a 230V mains supply Connecting to a different mains voltage will result in improper operation or even destructi...

Page 9: ...ocks have been operated and that the equipment is ready for use 6 Perform interlock check by doing the following Activate the red X RAY ON button on the front control panel Observe that all X ray ligh...

Page 10: ...on an inadequate support or try to lift it unaided If the unit is dropped do not attempt to resume operation before consulting a qualified service technician The user must be aware that excessive radi...

Page 11: ...m until it has been checked by a suitably qualified engineer and a successful radiation check carried out 6 In the event of any concern regarding the safe operation of the SCANMAX contact your supplie...

Page 12: ...w x ray dose X ray beam limiting Interlock system X ray On indicators Lead Shielding In the United Kingdom the requirement is a leakage rate as low as is practicable but in no case to exceed 1 micro S...

Page 13: ...the area for closer examination and press the left hand key and the image will be enlarged by a factor of 2 Zoom x 2 If a further close look is required press the left hand key again for x4 or x8 and...

Page 14: ...the camera to synchronise to the monitor Lines will appear across the film if it not synchronised to ensure good depth of field black and white film will tend to give higher apparent contrast If used...

Page 15: ...ted should be treated with extreme caution 4 If the item appears suspicious security staff should be alerted and the appropriate security procedures implemented SCANNA strongly recommend that users of...

Page 16: ...formed by the customer Line Grounding and Regulation Regulation When the unit is energised the line voltage should drop no more than 5 at the wall outlet Any further drop indicates that your AC power...

Page 17: ...connect the in line plug socket to the x ray source S4 Remove the x ray generator from the case Caution The x ray generator is heavy two persons are required for this task S5 Pack the x ray generator...

Page 18: ...m left to right if needed S4 Test for radiation leakage and correct as needed You must reject the unit at this point if levels of 1 Sv hr are exceeded Final re seating of the door should be performed...

Page 19: ...until the image on the screen is suitable Remember to return to f1 6 before replacing the side panel The camera lens can be focused on its own image reflected from the lead glass in the base of the i...

Page 20: ...View of front panel View of rear panel From Left 1 Mains input with fuse under 2 Mains isolating switch 3 Mains for Monitor if applicable From bottom 4 Remote X ray On 5 SVGA video Out 6 Trackball...

Page 21: ...View of controller with rear panel open...

Page 22: ...e regulations Equipment Serial No Item Check Result Comment 1 Check Indicators 2 Check switch operation 3 Check door operation and interlock 4 Clean equipment internally 5 Check X ray generator 6 Chec...

Page 23: ...18 Area Back Panel Area Lid Back No Name No Name 4 5 4 Left Vertical Seam 19 Back Lid Seam 5 Right Vertical Seam 20 Right Lid Seam 6 6 Back Panel Top 19 21 Front Lid Seam 7 Electrical Plug 22 Left Li...

Page 24: ...110 100 VAC 10 50 60 HZ Single Phase X Ray Source Focal Spot 1 5 mm Anode Angle 35 degrees Anode Type Stationary Kvp 65 KV 85KV max Tube Current 7 mA 20mA max Cooling method Oil cooled Resolution 36 A...

Page 25: ...stem Internal Resolution 752 X 582 Lens Mount C Mount Minimum illumination 0 02 Lux F1 4 Output Voltage will work to 0 011x Cpu BOARD 2MB DRAM 512KB Flash 30 150 MIPS Video Output Monochrome CCIR Colo...

Page 26: ...2 lux for excellent picture quality Picture burn in does not occur Excellent immunity to vibration and shock The camera interface uses solid state components and requires no periodical maintenance wor...

Page 27: ...REPAIRS A one year warranty is provided on the labour performed and any new parts installed by service technician at SCANNA s premises This warranty is limited to labour performed and parts installed...

Page 28: ...O 1 Don t try to open it 1 Keep calm 2 Don t press squeeze or prod it 2 Look for sender s name on the back 3 Don t put it in sand or water 3 Check with the sender 4 Don t put it in a container 4 Check...

Page 29: ...oor open If faulty replace fuse blows again check with door closed Check bulb If faulty replace Change controller and x ray generator If faulty replace 2 System Ready Is System Ready light on No Check...

Page 30: ...faulty replace 3 Dim Picture Is there a large object in the viewing chamber Remove and check with an empty chamber Is fluorescent screen damaged Replace fluorescent screen Is the TV Camera lens dirty...