Scan Helicopter – Manual
- 19 -
4.4 Maintenance and inspection list
Daily
§
Inspect the trowel head
§
Look for any other damage
12 hours after service
§
Tighten all screws
4.5 Cleaning the machine
Before starting to clean the machine, make sure it is in its” Safety off position”
The power must not be connected while cleaning the machine.
Do not use highly pressurized water to clean the machine.
Water and soap is recommended.
4.6 Trouble shooting
4.6.1 Common faults
Symptom
Cause
Correction
A
3
The machine won’t start
§
There is a power failure from the power supply
§
Inspect the fuses in the worksites fuse box
§
Inspect cables
§
Measure that the main voltage is present and at full voltage
at the cable end near the machine.
O
E
E
The machine only works for
short periods
§
The motor is overheated
§
Wait until the motor is cool again
O
§
The control device is damaged
§
Replace the control device
S
The machine is weak and
might stop when on the
ground.
§
There is a voltage drop at the power supply
§
Inspect the fuses in the worksites fuse box
§
Inspect cables
§
Measure that the main voltage is present and at full voltage
at the cable end near the machine.
§
Make sure that the cable is not too long. If the cable should
be too long, use a cable with higher rating to a distribution
box nearer the machine.
O
E
E
O
47
ENGLISH
SCAN HELICOPTER POWER TROWEL
www.scanmaskin.com
Summary of Contents for Scan Helicopter
Page 1: ...SCAN HELICOPTER POWER TROWEL MANUAL...
Page 29: ...ANTECKNINGAR www scanmaskin se 29 SVENSKA ELDRIVEN BATTERIDRIVEN GL TTNINGSMASKIN...
Page 57: ...NOTERINGAR NOTES 57 ENGLISH SCAN HELICOPTER POWER TROWEL www scanmaskin com...
Page 58: ...NOTERINGAR NOTES 58 www scanmaskin com...
Page 59: ...NOTERINGAR NOTES 59 ENGLISH SCAN HELICOPTER POWER TROWEL www scanmaskin com...