Scan Combiflex 450 – Manual
Chapter 5
- 62 -
5.6.2 Error codes SC-450 NS
Table 0-1
Error codes
Alarm codes starts with “A” and fault codes starts with “F”. The machine will be operational if an alarm
code is present but not when an fault code is present.
The following table describes the access for the task.
Abbreviation Person
O
Machine Operator
E
Electrician
S
Scanmaskin certified service technician
Table 0-2
Access rights for different persons
7
See access table ”Table 0-2”
Code
Description
Cause
Correction
A
7
A2001
Over current
§
One of the three phases is missing from the
power supply
§
There is a voltage drop at the power supply
§
Inspect the fuses in the worksites fuse box
§
Inspect cables
§
Measure that all three phases are present and at
full voltage at the cable end near the machine
§
Make sure that the cable is not to long. If the
cable should be to long, use a cable with higher
rating to a distribution box nearer the machine
O
O
E
E
§
The environmental temperature is too high. When
the temperature is above 40°C (104°F) the
inverter will decrease its maximum output current
§
Inspect the ventilation fans
§
Inspect the filters to the fans
O
O
A2002
Over voltage
§
The power supply has got voltage transients
§
Inspect the power source
E
A2003
Under voltage
§
One of the three phases is missing from the
power supply
§
There is a voltage drop at the power supply
See A2001
A2006
Speed reference
error
§
The potentiometer on the control panel is
damaged
§
Inspect the potentiometer
§
Replace if necessary
S
S
A2009
Over
temperature
§
The internal temperature in the inverter is above
120°C (248°F). This could be caused by faulty
ventilation in the electrical cabinet.
§
Inspect the ventilation fans
§
Inspect the filters to the fans
§
Contact Scanmaskin Sweden AB
O
O
A5001
Internal error
Contact Scanmaskin Sweden AB
F0001
Over current
See A2001
F0002
Over voltage
See A2002
F0003
Over
temperature
§
The internal temperature in the inverter is above
135°C (275°F). This could be caused by faulty
ventilation in the electrical cabinet.
See A2009
F0004
Short circuit in
motor
§
The cable to the motor has been damaged
§
The motor has been damaged
§
Inspect the motor cable
§
Inspect the motor connection
§
Contact Scanmaskin Sweden AB
E
E
F0006
Under voltage
See A2003
F0007
Speed reference
error
See A2006
F0016
Protective earth
failure
§
The cable to the motor has been damaged
§
The motor has been damaged
§
Water have entered the motor
§
Inspect the motor cable
§
Inspect the motor connection
§
Contact Scanmaskin Sweden AB
E
E
F0018
Internal error
Contact Scanmaskin Sweden AB
F0021
F0022
Power supply
phase fault
See A2003
F0034
Motor phase
fault
§
One of the three phases to the motor is missing.
This could be due to damage to the motor cable
or to the motor.
§
Inspect the motor cable
§
Inspect the motor connection
§
Contact Scanmaskin Sweden AB
E
E
Scan Combiflex 450 – Manual
Chapter 5
- 63 -
6 Spare parts
6.1 Gear barrel
62
63
ENGLISH
www.scanmaskin.com
www.scanmaskin.com
SCAN COMBIFLEX 450/450NS