RS-232 Control:
In RS-232 extender mode, user could use RS-232 port of transmitters to operate/setup the receivers at
same channel by program like Hyper Terminal which built-in Windows XP and before version.
Hyper Terminal setting:
〔
115200 bps (8-N-1),
Flow control: None
〕
(Properties -> Settings -> ASCII
Setup
…
and select
“Send line ends with line feeds”
&
”Echo typed characters locally”
)
★
We recommend set the RS232 routing for all receivers to one transmitter to avoid RS232 connection
broken by video channel switching.
Command format: >CMD_Address> Command Parameters
Address, command and parameters are char, not hex code
Enter (LF or CR+LF) is required to execute the command
All accord receivers will run the command and parameters, we also add 3 kinds of user defined numbers
except MAC & IP (Device No
、
Group No
、
Party No) for flexible application:
Mxxxxxx
The last 6 digits of MAC Address of receiver
e.g.: 2218680123AB = M0123AB
Ixxxx
The last 2 column of IP Address (HEX) of receiver
e.g.: 169.254.012.034 = I0C22
Dxxx
Device No
e.g.: Device No 123 = D123
Gxx
Group No
e.g.: Group No 12 = G12
Pxx
Party No
e.g.: Party No 34 = P34
Cxxx
Channel No
e.g.: Channel 123 = C123
ALL
All receivers
Response format: <ACK_Address< Response character
Receivers will response message to transmitter as above format and send Newline after
When send command to multiple receivers(address as Gxx, Pxx, Cxxx, and ALL) they will not response.