SCAN 45i Installation And Operation Instructions Manual Download Page 27

27

139234_Rev_A    9.17 .10

No.  Part Number  Description

223973 

Ribbon Burner 

2-32  157266 

Spud Assembly, Complete 

129472 

Orifice, Pilot - #51 (NG, Pop-Top)

 

222057 

Orifice, Pilot - #35 (LP)

222925 

Proflame Pilot, NG

117917 

Screw, HWH SMA 8 x 1/2 SL Blk Oxide

22395292 

Spud Cover Plate,  Matte Black 

129669 

Gasket, Spud Plate Assembly

223244 

Bracket, IPI Ignition Board

222924 

Proflame IPI Ignition Board

117922 

Nut, Hex M4 DIN 934 PLAIN

10 

129154 

Terminal Block, 2 Pole 77 series

11 

223986 

Face Plate, Burner / Pilot, Silk Screened

12 

120517 

Switch, Rocker, SPST, Black, Plain

13 

117921 

Screw, Pan Head Ph M4 X 12 8.8 M/S- Blk Oxide

14 

220703 

Switch, Rocker, SPDT, Center Off, Black, Plain

15 

223953 

Valve Bracket

16 

223901 

Heat Shield, Valve

17 

129670 

Gasket, Pilot Assembly

18 

223254 

Plug, Pilot Thermopile (For IPI Pilot)

19 

222292 

Elbow, 90°, Brass 3/8 NTP X 3/8” Dia Tube

20 

118214 

Screw, #8 X 1/4”, Taptite, SLHWH, SZPL

21 

223980 

Proflame Valve, Manual Hi/Lo, NG

22 

223215 

Adaptor, Straight, Brass, 3/8 NTP x 3/8” Dia Flare

23 

129707 

Flex tube w/connectors (3/8” O.D. x 24”)

24 

222280 

Gasket, Drop In Orifice Holder

25 

223231 

Orifice Holder, Drop In Assembly

26 

220641 

Orifice, #33 - NG

 

045025 

Orifice, #52 / LP

27 

117975 

Nut,Wing M6 Zinc

28 

118029 

Washer, Fender .250 x 1.500 dia.

29 

221107 

Gasket, Primary Air Shutter

30 

224104 

Handle, Air Shutter, Internal,  

31 

221390 

Primary Air Shutter Assembly

32 

157264 

SIT Proflame DFC Wire Harness 

33 

157265 

Battery Box Assembly  

34 

22410792 

Battery Shield, Matte Black

35 

117975 

Wing Nut, M6

36 

129730  

Regulator Knob Extension

37 

118095 

Screw,  HWA, SMA 8 mm x 1”

38 

225350 

Pilot Spacer,  1/2”

39 

220546 

Pilot Spacer,  .31”

Not illustrated

37 

224190 

Stainless Steel Burner Skirt

38 

22397892 

Burner Media Retainer Tray

39 

22417492 

Inner Retainers (2)

40  223977 

Burner Support

No.  Part Number  Description

ONLY USE 

REPLACEMENT PARTS 

PROVIDED BY AN 

AUTHORIZED  

JØTUL DEALER.

Scan

 45

Replacement Parts

32

Figure 39.  Burner and Spud Assembly

Summary of Contents for 45i

Page 1: ...l Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trou vant dans le b timent o vous trouvez Appelez imm diatement votre fournis seur de gaz depuis un voisin Suivez les instructions...

Page 2: ...ucts be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURN...

Page 3: ...the glass out of the way 5 The Starfire Glass Embers or Tumbled Stone burner media is packaged separately from the insert firebox Figure 1 Pull each Trunk Latch down to disengage it from the Glass Fr...

Page 4: ...an 45i gas fireplace insert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21 88 2009 CSA 2 33 2009 CAN CGA 2 17 M91 and CSA P 4 01 2 for Canada Starfire Glass Em...

Page 5: ...ve been established in CAN CGA B149 Fuel Installation Code Installer l appareil selon les codes ou reglements locaux ou en l absence de tels reglements selon les Codes d installation CAN CGA B149 5 Do...

Page 6: ...ace Never burn any solid materials wood cardboard paper coal etc in this gas fireplace Use with natural gas or propane fuel ONLY Any safety screen glass or guard removed for servicing the appliance mu...

Page 7: ...tallation of the brackets allows the insert to be raised up to 2 1 2 off of the hearth Also note that use of the leveling brackets will affect required minimum clearance to combustible top trim and ma...

Page 8: ...18 forward of the firebox glass panel Raised Hearth A raised hearth that is at least 6 high requires a non combustible hearth that extends a minimum 12 from the fireplace glass and and is a minimum o...

Page 9: ...ment This appliance requires 120 V AC power to operate the blower accent lamps and electronic ignition Four AA batteries provide back up power in case of a power outage Leg Leveler Bolts and Brackets...

Page 10: ...3 M99 TEST METHODS AND RESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Vent Guidelines All vent compo...

Page 11: ...into the chimney flue and ultimately into the intake duct to the insert 9 Compress the ducts so that they are hanging above the height of the fireplace opening and are out of the way 10 Position the i...

Page 12: ...ESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Figure 9 Venting through prefabricated fireplace chimn...

Page 13: ...ut holes for both the intake and exhaust liners in the block off plate C A direct vent cap is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D A...

Page 14: ...13 85 WC NECESSARY MANIFOLD PRESSURES inches water column MIN MAX NATURAL GAS 1 6 WC 3 5 WC PROPANE 5 3 WC 11 0 WC ALWAYS TEST PRESSURE WITH THE VALVE REGULATOR ADJUSTED TO THE HIGHEST SETTING Figure...

Page 15: ...ilot rectification and or frequent burner outages Little variation in flame picture between HI and LO regulator settings Insufficient gas to support more than one ap pliance causing nuisance outages o...

Page 16: ...BLIS DANS LES IN STRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L EQUIPEMENT Conversion Kit LP 157249 NG 157250 Tools required 1 2 13 mm open end wrench or deep well socket Torx T20 driver 1 4 nut driv...

Page 17: ...ocated it should not be able to move to the right or left 10 Replace the variable regulator on the gas control valve Using a Torx T 20 screwdriver remove the two screws from the regulator tower on the...

Page 18: ...aller and applied to the appli ance at the time of the conversion See fig 19 Derating procedure 1 Turn off gas supply to the appliance and disconnect from electrical power source 2 Remove the Glass Fr...

Page 19: ...ening the air shutter will generate a flame that is blue and transparent or an anemic flame This flame is generally more efficient but not very attractive We recommend the following settings for the S...

Page 20: ...shutter See figs 14 and 15 pages 16 17 4 Use a 10 mm socket to remove the left and right burner bracket nuts Remove the Burner Bracket from the firebox See fig 23 5 Bend the two upper rear tabs down...

Page 21: ...ure 26 Install Glass Embers Tumbled Stones Kit 157245 NOTE Install the optional Reflective Glass Panels before installing the stones Spread the stones evenly around the burner media tray CAUTION Take...

Page 22: ...Figure 28 At the thermostat the two wires should be connected to the two connection screws on the thermostat base plate according to the manufacturer s instructions For the thermostat to function the...

Page 23: ...e Backing Plate or Trimmable Backing Plate See fig 31 Starting at the small precut slot use a straight edge to draw a guideline across the leg Use a disk grinder to cut off the excess material and fil...

Page 24: ...there is no call for heat Ideal for use with thermostatic or remote control this feature ignites the pilot flame only when there is a call for heat A battery back up permits continued use in the event...

Page 25: ...not lifting or float ing The flame should be blue in color around the pilot hood with traces of yellow toward the outer edges It is important that the pilot flame engulf the top 1 8 of the flame recti...

Page 26: ...s and particulate accumulation may appear on the inside surface to the glass Use a dampened soft cloth to clean the glass and polish with a dry soft towel Specially formulated ceramic glass cleaner ma...

Page 27: ...214 Screw 8 X 1 4 Taptite SLHWH SZPL 21 223980 ProflameValve Manual Hi Lo NG 22 223215 Adaptor Straight Brass 3 8 NTP x 3 8 Dia Flare 23 129707 Flex tube w connectors 3 8 O D x 24 24 222280 Gasket Dro...

Page 28: ...Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk Oxide 2 222799 Blower Bracket 3 222072 Blower TransFlow 12 Cage 120 CFM No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk...

Page 29: ...rs Simpson Dura Vent Inc P O Box 1510 Vacaville CA 95696 1510 800 835 4429 Selkirk Corporation 1301 W President George Bush Hwy Suite 330 Richardson TX 75080 1139 800 992 8368 American Metal Products...

Page 30: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Page 31: ...ouch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone If your gas supplier cannot be reached call the fire department 1 Set the...

Page 32: ...ion it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification color or ty...