14
© 2021 Scan Electronics Ltd.
Standalone usage
The menu is organized cyclically at all levels. For example, pressing the
swing
button "
down
" on the top
level of menu moves the focus from item to item in the following order:
-->
-->
-->
-->
-->
-->
--> etc...
General structure of the menu is shown below.
[Settings]
– transition to device settings submenu .
·
[Display units]
– choice between presentation of dose rate and count rate for
also
).
·
[Measurement units]
– transition to submenu.
– [Dose]
– selection of the units:
[Sv
(Sievert)
]
/
[R
(Roentgen)
]
– [Count rate]
– selection of the units:
[CPS
(counts per second)
]
/
[CPM
(counts per minute)
]
– [< Back]
– return to a higher level, presented in all submenus;
– [<< Menu quit]
– return to selected display mode, presented in all submenus;
*
further, the last two points
[< Back]
and
[<< Menu quit]
are designated as
[< <<]
·
[Dose rate]
– transition to submenu.
– [Alarm 1]
– setting alarm threshold 1 for the dose rate;
– [Alarm 2]
– setting alarm threshold 2 for the dose rate;
– [< <<];
·
[Dose]
– transition to submenu.
– [Alarm 1]
– setting alarm threshold 1 for the accumulated dose;
– [Alarm 2]
– setting alarm threshold 2 for the accumulated dose;
– [< <<];
·
[Screen]
– transition to submenu.
– [Backlight]
– transition to submenu;
– – [Turning on]
- backlight turninig-on mode:
[Auto]
/
[Never]
/
[By button]
;
– – [Duration]
- backlight turninig-off timeout:
[5 s]
,
[10 s]
,
[15 s]
,
[30 s]
– – [Brightness]
- backlight brightness level: from
[0]
to
[9]
– – [< <<];
– [Rotate]
– image orientation mode:
[Auto]
/
[Right]
/
[Left]
;
– [< <<];
·
[Signals]
– transition to submenu.
– [Sound]
– selection
[On]
/
[Off]
, for all sounds
– [Vibro]
– selection
[On]
/
[Off]
, for all vibration signals
– [Light]
– selection
[On]
/
[Off]
, light flash for a radiation quantum registration, separately
– [Clicks]
– selection
[On]
/
[Off]
, sound for a radiation quantum registration, separately
– [Buttons]
– transition to submenu
– – [Sound
] – selection
[On]
/
[Off]
, sound for pressing the buttons, separately
– – [Vibro]
– selection
[On]
/
[Off]
, vibration for pressing the buttons, separately
– – [< <<];
– [Alarms]
– transition to submenu.
– – [Dose rate]
– transition to submenu.
– – – [Alarm 1]
– transition to submenu.
– – – – [Sound]
– selection
[On]
/
[Off]
– – – – [Vibro]
– selection
[On]
/
[Off]
– – – – [< <<];
– – – [Alarm 2]
– transition to submenu.
– – – – [Sound]
– selection
[On]
/
[Off]
– – – – [Vibro]
– selection
[On]
/
[Off]
– – – – [< <<];
– – – [Out of scale]
– transition to submenu.
– – – – [Sound]
– selection
[On]
/
[Off]
– – – – [Vibro]
– selection
[On]
/
[Off]
– – – – [< <<];
– – [Dose]
– transition to submenu.
– – – [Alarm 1]
– transition to submenu.
– – – – [Sound]
– selection
[On]
/
[Off]
– – – – [Vibro]
– selection
[On]
/
[Off]
Summary of Contents for RadiaCode-101