![SBM 12 ZRFA Technical Instructions Download Page 7](http://html1.mh-extra.com/html/sbm/12-zrfa/12-zrfa_technical-instructions_1205222007.webp)
7
CLEAN THE HEATER ONCE A YEAR
(or more often if the flame becomes blue):
- remove the injector block.
- clear the injector using a soft wire.
- blow compressed air inside the burner body.
JOINTS
AIR COMPRIME
3 à 5 bar MAXI
NE PAS SOUFFLER LES JOINTS
ENTRE LES CERAMIQUES
- check the condition of the ceramic plaques (visual check).
- check the heater attachments.
- check the tightness of all accessories
6. GAS CONVERSION :
The heaters are designed to operate with the following gas :
CATEGORY :
GAS :
PRESSURE :
I
3P
GB/IE/TR
G31 (PROPANE)
148 mbar
I
2H
GB/IE/TR
G20 (NATURAL GAS)
148 mbar
The equipment is adjusted for the type of gas and the pressure as displayed on
the rating plate. For any change of the gas used, please contact your SBM
representative.
COMPRESSED AIR
3 to 5 bar max.
DO NOT AIM AT THE JOINTS
BETWEEN THE CERAMIC PLAQUES