SBM 12 ZRFA Technical Instructions Download Page 3

 

 

2. SAFETY INSTRUCTIONS : 

 

THE HEATERS SHOULD BE INSTALLED AND MAINTAINED IN 

SUFFICIENTLY VENTILATED PREMISES BY A QUALIFIED INSTALLER 

ACCORDING TO CURRENT SAFETY REGULATIONS. 

NOT AUTHORISED FOR USE IN DOMESTIC PREMISES.

 

 
 

TO BE INSTALLED IN COMPLIANCE WITH  

CURRENT REGULATIONS  

AND IN 

SUFFICIENTLY VENTILATED PREMISES

 

 
 
2.1 HEATER INCLINATION 
 

 

 
2.2 INCLINATION OF HEATERS 212 FA AND 216 FA 
 

30°

30°

212 FA

216 FA

0,37m

0,50m

 

 

TAKE CARE TO MOUNT THE BRACKET CORRECTLY 

6/8 ZRFA

 

2/3 ZRFA

 

12/16 ZRFA

 

Summary of Contents for 12 ZRFA

Page 1: ...AY FRANCE 1 GAS CERAMIC HEATING FA HEATERS TECHNICAL INSTRUCTIONS N 05000077 6 GAS HEATING FOR POULTRY AND LIVESTOCK 1 TECHNICAL SPECIFICATIONS 2 SAFETY INSTRUCTIONS 3 IGNITING OF HEATERS 4 SHUTT OFF...

Page 2: ...sumption m3 h 0 086 0 133 0 296 0 350 0 530 0 688 1 005 1 323 G20 NG 180mbar Consumption m3 h 0 095 0 145 0 326 0 386 0 585 0 759 1 108 1 459 prim inject 1 100mm injector 1 100mm 48 57 none 54 80 95 9...

Page 3: ...G TO CURRENT SAFETY REGULATIONS NOT AUTHORISED FOR USE IN DOMESTIC PREMISES TO BE INSTALLED IN COMPLIANCE WITH CURRENT REGULATIONS AND IN SUFFICIENTLY VENTILATED PREMISES 2 1 HEATER INCLINATION 2 2 IN...

Page 4: ...of minimum safety heights with respect to the ground MODEL MINI HEIGHT m 2 ZRFA 0 30 3 ZRFA 0 30 6 ZRFA 0 50 8 ZRFA 0 50 12 ZRFA 0 50 16 ZRFA 1 00 212 FA 1 00 216 FA 1 00 For pratical hanging heights...

Page 5: ...supply Adjust the VisioLon Elv T set point to the temperature required for the animals Ignition of the heaters is automatically controlled by the VisioLon Elv T Valve B10F or valve NPT Sensor A1 supp...

Page 6: ...FF OF HEATERS Close the main gas valve Switch off the installation power supply 5 MAINTENANCE ONCE A WEEK or more frequently if the flame becomes blue remove the filter box remove the dust from the fi...

Page 7: ...visual check check the heater attachments check the tightness of all accessories 6 GAS CONVERSION The heaters are designed to operate with the following gas CATEGORY GAS PRESSURE I3P GB IE TR G31 PRO...

Page 8: ...ched to the heater A B C D E F G H J Rep PIECE Ref SBM Condent A THERMOCOUPLE 9802001 1 B MAGNETIC HEAD 9803001 1 C 10 MEDIAS 115 1 2 3 6 8 ZRFA 3800000 10 C 10 MEDIAS 160 12 16 ZRFA 3800012 10 C 10 M...

Page 9: ......

Page 10: ...TO BE DISPLAYED NEXT TO THE CONTROL UNIT...

Page 11: ...e MINI gas regulator to obtain the temperature required for the animals CASE No 2 The heaters are off Set the MINI gas regulator to 10 Open the main valve Press the push button while applying a flame...