![SBM 12 ZRFA Technical Instructions Download Page 11](http://html1.mh-extra.com/html/sbm/12-zrfa/12-zrfa_technical-instructions_1205222011.webp)
Manufacturer : SBM
3, Cottages de la Norge
21490 CLENAY - FRANCE
Installer's stamp :
1312
GAS CERAMIC HEATING
FA HEATER INSTRUCTIONS FOR USE
N° 05000077/6
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
A U T O M A T I C R E G U L A T I O N
VisioLon Elv-T module and G6A or G10A gas regulation
IGNITION:
Open the main valve.
Set MAXI gas regulator to 10, MINI to:
-
for all types of heater except 216FA.
-
for 216FA.
Switch on the power supply.
Adjust the VisioLon Elv-T set-point to the temperature required for the animals.
Ignition of the heaters is automatically controlled by the VisioLon Elv-T.
SHUTTING DOWN:
Close the main valve.
Switch off the power supply.
CURRENT FAILURE:
CASE No.1: Heaters operating at MINI.:
Adjust the operating pressure using the MINI gas regulator, to obtain
the temperature required for the animals.
CASE No.2: The heaters are off :
Set the MINI gas regulator to 10.
Open the main valve.
Press the push-button while applying a flame to the surface of
the ceramic plaques. Continue to press the push-button for 30
seconds.
Regulate heater power by adjusting the MINI gas regulator.
When switching on the power again, adjust the MINI gas
regulator to 1.
MAINTENANCE:
CLEAN THE FILTER ONCE A WEEK
(or more frequently if the flame becomes blue)
- remove the filter box.
- remove the dust from the filter media.
CLEAN THE HEATER ONCE A YEAR
(or more frequently if the flame becomes blue)
- remove the injector block.
- clear the injector using soft copper wire.
- blow compressed air inside the burner body.
- check condition of ceramic plaques (visual check).
- check the heater attachment.
- check accessory seals.
compressed air
3 to 5 bar max
do not aim at the joints between the ceramic plaques
Summary of Contents for 12 ZRFA