SBM 12 ZRFA Technical Instructions Download Page 2

 

 

1. TECHNICAL SPECIFICATIONS : 

 

Refer to the heater rating plate attached to the filter support 

 

 
 
 

see example opposite : 

 

 

MODEL 

ZRFA 

ZRFA 

ZRFA 

ZRFA 

12 

ZRFA 

16 

ZRFA 

212 

FA 

216 

FA 

 

  certificate number 

1312 AR 1201 

 

Weight (kg)

 

1.55 

1.70 

2.10 

2.50 

3.00 

3.50 

6.50 

7.80 

 Nominal heat flow  
 

Qn (kW) Hi (148mbar) 

0.80 

1.25 

2.80 

3.30 

5.00 

6.50 

9.50  12.50 

 Max. heat flow 

 

 

Qm (kW) Hi (180mbar) 

0.88 

1.38 

3.09 

3.60 

5.50 

7.16  10.48  13.78 

 

 

G20 (NG 148mbar)

 

 Consumption (m

3

/h) 

0.086  0.133  0.296  0.350  0.530  0.688  1.005  1.323 

 

G20 (NG 180mbar)

 

 Consumption (m

3

/h) 

0.095  0.145  0.326  0.386  0.585  0.759  1.108  1.459 

 Ø prim inject (1/100mm) 
 Ø injector (1/100mm) 

48 
57 

none 

54 

80 
95 

95 

100 

110 
135 

125 
150 

2x110 
2x120 

2x132 
2x132 

 

 G31

 

(Propane 148mbar)

 

 Consumption (kg/h) 

0.062  0.098  0.220  0.260  0.390  0.510  0.740  0.980 

 G31

 

(Propane 180mbar)

 

 Consumption (kg/h) 

0.068  0.108  0.242  0.286  0.430  0.562  0.816  1.080 

 Ø injector (1/100mm) 

35 

40 

58 

65 

78 

95 

2x76  2x90 

 
 
The correct operation of the heaters requires the renewal of 1 m

3

/h new air per kW 

of heating installed. This air renewal is additional to that required by the animals. 

Summary of Contents for 12 ZRFA

Page 1: ...AY FRANCE 1 GAS CERAMIC HEATING FA HEATERS TECHNICAL INSTRUCTIONS N 05000077 6 GAS HEATING FOR POULTRY AND LIVESTOCK 1 TECHNICAL SPECIFICATIONS 2 SAFETY INSTRUCTIONS 3 IGNITING OF HEATERS 4 SHUTT OFF...

Page 2: ...sumption m3 h 0 086 0 133 0 296 0 350 0 530 0 688 1 005 1 323 G20 NG 180mbar Consumption m3 h 0 095 0 145 0 326 0 386 0 585 0 759 1 108 1 459 prim inject 1 100mm injector 1 100mm 48 57 none 54 80 95 9...

Page 3: ...G TO CURRENT SAFETY REGULATIONS NOT AUTHORISED FOR USE IN DOMESTIC PREMISES TO BE INSTALLED IN COMPLIANCE WITH CURRENT REGULATIONS AND IN SUFFICIENTLY VENTILATED PREMISES 2 1 HEATER INCLINATION 2 2 IN...

Page 4: ...of minimum safety heights with respect to the ground MODEL MINI HEIGHT m 2 ZRFA 0 30 3 ZRFA 0 30 6 ZRFA 0 50 8 ZRFA 0 50 12 ZRFA 0 50 16 ZRFA 1 00 212 FA 1 00 216 FA 1 00 For pratical hanging heights...

Page 5: ...supply Adjust the VisioLon Elv T set point to the temperature required for the animals Ignition of the heaters is automatically controlled by the VisioLon Elv T Valve B10F or valve NPT Sensor A1 supp...

Page 6: ...FF OF HEATERS Close the main gas valve Switch off the installation power supply 5 MAINTENANCE ONCE A WEEK or more frequently if the flame becomes blue remove the filter box remove the dust from the fi...

Page 7: ...visual check check the heater attachments check the tightness of all accessories 6 GAS CONVERSION The heaters are designed to operate with the following gas CATEGORY GAS PRESSURE I3P GB IE TR G31 PRO...

Page 8: ...ched to the heater A B C D E F G H J Rep PIECE Ref SBM Condent A THERMOCOUPLE 9802001 1 B MAGNETIC HEAD 9803001 1 C 10 MEDIAS 115 1 2 3 6 8 ZRFA 3800000 10 C 10 MEDIAS 160 12 16 ZRFA 3800012 10 C 10 M...

Page 9: ......

Page 10: ...TO BE DISPLAYED NEXT TO THE CONTROL UNIT...

Page 11: ...e MINI gas regulator to obtain the temperature required for the animals CASE No 2 The heaters are off Set the MINI gas regulator to 10 Open the main valve Press the push button while applying a flame...

Reviews: