OPERATION INSTRUCTIONS 

Opening and closing the damper 

A. Open the damper before starting a fire. 

• Pull handle down slightly and release, allowing lug to 
pull up and hang freely about 7” above the bracket. 
(see illustration). If lug only hangs 1” to 2” above 
bracket, damper may not be open. 

Warning: Do not start a fire if damper is not clearly 
open. Failure to follow this rule may cause smoke 
damage. 

 

B. Close the damper after the fire is completely out. 

• Pull handle down until lug is below bracket. Move 
cable into any notch in bracket and release handle. 

C. If damper does not open 

• This may occur due to heavy snow, ice, or improper 
installation. 
• Pull the handle down sharply 3” to 4” below the 
bracket. This pulls down the extra cable leg to pull the 
lid open. 
• Release the lug up past the bracket. 
• If necessary, inspect the damper on your roof to 
determine how to get it open, or call your local CSIA or 
WETT certified chimney sweep to do the inspection. 

 

 
Energy saving note: Closing the damper when 
fireplace is not in use will prevent heated or air 
conditioned air from escaping out the chimney 

 

 

Fire prevention warning: Remember to have your flue checked annually for creosote 
buildup by your local CSIA or WETT certified chimney sweep. 

 

 
 

Summary of Contents for AC02740

Page 1: ...r manufacturer s workmanship Proof of purchase will be required to save your receipt A Return Goods Authorization Number need to be returned to our facility prepaid at 250 rue de Copenhague Saint Augustin de Desmaures Québec Canada G3A 2H3 SBIHA shall not be liable for any consequential or identical damages resulting in loss from the use of this product In no case will SBIHA s liability exceed the...

Page 2: ...mneys are difficult to access SBI Heating Accessories recommends that you call your local CSIA or WETT certified chimney sweep to install your new damper and clean your chimney at the same time This will not only help with the installation but will help ensure that your flue is in good working condition SAFETY PRECAUTIONS As with any product you install especially on your roof there are safety pre...

Page 3: ...n damper is closed Lower unattached end of cable to fireplace opening below C Adhere damper to the flue liner Use the adhesive cap to open the tube Apply adhesive to top of flue liner all the way around the opening Important Use only the adhesive furnished Caution Direct contact with adhesive will irritate eyes or skin Read directions on tube carefully Keep adhesive out of reach of children Press ...

Page 4: ... Placement of Bracket in Firebox B Install cable handle Pull cable through bracket until a slight tension can be felt Damper should now be closed Slide brass lug onto cable 1 2 above bracket see illustration Close damper by pulling cable down and placing lug under bracket Illustration Call Outs Cable Lug Bracket Handle Bracket and Handle Assembly C Check and adjust operation Return to the roof and...

Page 5: ... notch in bracket and release handle C If damper does not open This may occur due to heavy snow ice or improper installation Pull the handle down sharply 3 to 4 below the bracket This pulls down the extra cable leg to pull the lid open Release the lug up past the bracket If necessary inspect the damper on your roof to determine how to get it open or call your local CSIA or WETT certified chimney s...