background image

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS 

STEP 1: BEFORE GOING ON THE ROOF 

Check that all parts are present 

• 

Damper assembly: damper, cable, cable spring 

• 

Adhesive tube (1) 

• 

Allen wrench (1) 

• 

Bracket (1) 

• 

Chain assembly: chain, brass lug, handle (1) 

• 

Nail anchors (2) 

If any parts are missing, call SBI Heating Accessories: 
418-908-8002 

 

 

 

STEP 2: ON THE ROOF 

A. Carry damper and adhesive to roof 

B. Prep flue liner and damper 

• 

Make certain top of flue liner

 

is dry and clean.

 

• 

Be certain 4 inch spring will hang freely from lid 
when damper is closed.

 

• 

Lower unattached end of

 

cable to fireplace 

opening

 

below.

 

 

C. Adhere damper to the flue liner 

• 

Use the adhesive cap to open the tube. 

• 

Apply adhesive to top of flue liner all the way 

around the opening. 

Important: Use only the adhesive furnished. 

Caution: Direct contact with adhesive will irritate eyes 
or skin. Read directions on tube carefully. Keep 
adhesive out of reach of children. 

• 

Press the damper onto the flue liner. Allow 24 

hours to set before using fireplace. 

 

 

 

STEP 3:  AT THE FIREPLACE 

A. Mount bracket in fireplace 

• 

Using 1/4” masonry drill bit, drill one hole about 1” deep into firebrick towards 

 the front of the fireplace and about 20” off the firebox floor (see illustration).

 

Summary of Contents for AC02740

Page 1: ...r manufacturer s workmanship Proof of purchase will be required to save your receipt A Return Goods Authorization Number need to be returned to our facility prepaid at 250 rue de Copenhague Saint Augustin de Desmaures Québec Canada G3A 2H3 SBIHA shall not be liable for any consequential or identical damages resulting in loss from the use of this product In no case will SBIHA s liability exceed the...

Page 2: ...mneys are difficult to access SBI Heating Accessories recommends that you call your local CSIA or WETT certified chimney sweep to install your new damper and clean your chimney at the same time This will not only help with the installation but will help ensure that your flue is in good working condition SAFETY PRECAUTIONS As with any product you install especially on your roof there are safety pre...

Page 3: ...n damper is closed Lower unattached end of cable to fireplace opening below C Adhere damper to the flue liner Use the adhesive cap to open the tube Apply adhesive to top of flue liner all the way around the opening Important Use only the adhesive furnished Caution Direct contact with adhesive will irritate eyes or skin Read directions on tube carefully Keep adhesive out of reach of children Press ...

Page 4: ... Placement of Bracket in Firebox B Install cable handle Pull cable through bracket until a slight tension can be felt Damper should now be closed Slide brass lug onto cable 1 2 above bracket see illustration Close damper by pulling cable down and placing lug under bracket Illustration Call Outs Cable Lug Bracket Handle Bracket and Handle Assembly C Check and adjust operation Return to the roof and...

Page 5: ... notch in bracket and release handle C If damper does not open This may occur due to heavy snow ice or improper installation Pull the handle down sharply 3 to 4 below the bracket This pulls down the extra cable leg to pull the lid open Release the lug up past the bracket If necessary inspect the damper on your roof to determine how to get it open or call your local CSIA or WETT certified chimney s...

Reviews: