background image

 

 

 

 

 

 

 

WARNING 

The Top Damper Chimney Damper is made for use only with open woodburning 
masonry fireplace chimneys and are NOT suitable for use in these installations: 

 

Don’t use on chimneys serving vented gas logs. Vented gas logs require the 

fireplace damper to be removed completely or fixed to a permanently open 
position; this is to assure that soot, fumes and carbon monoxide do not enter 
your home. 

 

Use only on vent-free gas logs if approved by the appliance manufacturer and 

the local authority having jurisdiction. However, we don’t recommend it because 
the moisture generated from the gas logs could damage the chimney structure. 

 

Don’t use on chimneys serving other fuels, wood stoves or other appliances such 
as inserts, furnaces, etc. 

 

PROFESSIONAL INSTALLATION RECOMMENDED 

Some chimneys are difficult to access. SBI Heating Accessories recommends that you 
call your local CSIA or WETT certified chimney sweep to install your new damper and 
clean your chimney at the same time. This will not only help with the installation, but will 
help ensure that your flue is in good working condition. 

 

SAFETY PRECAUTIONS 

As with any product you install, especially on your roof, there are safety precautions, 
including: 

• 

Using a ladder and working on your roof in a safe manner; 

• 

Working on roof only in good weather, not in rain, ice, snow, or lightning; 

• 

Making sure the damper will open properly before starting a fire; 

• 

Using safety glasses when drilling; 

• 

Using a masonry bit when drilling into masonry; 

• 

Using only the adhesive provided. 

In addition, be sure to check local codes and the appliance manufacturer before 
installing on flues venting gas fireplaces or gas appliances. 

 

TOOLS NEEDED FOR INSTALLATION 

Hammer, power drill, 1/4” masonry drill bit, safety glasses, wire cutters, and ladder. 

Summary of Contents for AC02740

Page 1: ...r manufacturer s workmanship Proof of purchase will be required to save your receipt A Return Goods Authorization Number need to be returned to our facility prepaid at 250 rue de Copenhague Saint Augustin de Desmaures Québec Canada G3A 2H3 SBIHA shall not be liable for any consequential or identical damages resulting in loss from the use of this product In no case will SBIHA s liability exceed the...

Page 2: ...mneys are difficult to access SBI Heating Accessories recommends that you call your local CSIA or WETT certified chimney sweep to install your new damper and clean your chimney at the same time This will not only help with the installation but will help ensure that your flue is in good working condition SAFETY PRECAUTIONS As with any product you install especially on your roof there are safety pre...

Page 3: ...n damper is closed Lower unattached end of cable to fireplace opening below C Adhere damper to the flue liner Use the adhesive cap to open the tube Apply adhesive to top of flue liner all the way around the opening Important Use only the adhesive furnished Caution Direct contact with adhesive will irritate eyes or skin Read directions on tube carefully Keep adhesive out of reach of children Press ...

Page 4: ... Placement of Bracket in Firebox B Install cable handle Pull cable through bracket until a slight tension can be felt Damper should now be closed Slide brass lug onto cable 1 2 above bracket see illustration Close damper by pulling cable down and placing lug under bracket Illustration Call Outs Cable Lug Bracket Handle Bracket and Handle Assembly C Check and adjust operation Return to the roof and...

Page 5: ... notch in bracket and release handle C If damper does not open This may occur due to heavy snow ice or improper installation Pull the handle down sharply 3 to 4 below the bracket This pulls down the extra cable leg to pull the lid open Release the lug up past the bracket If necessary inspect the damper on your roof to determine how to get it open or call your local CSIA or WETT certified chimney s...

Reviews: