Ekinox Subsea
– Hardware Manual
EKINOXSUBSEAHM.1.4
7.5. Cables
7.5.1. CA-AEK-SUB-DPT500-10M
10 meters wire ended sub sea cable depth rated for 500 meters.
7.5.1.1. Cable Construction
This high quality subsea cable is wire ended on one side and has a Seacon MINIM-37#22-CCP-Ti connector
over-moulded on the other side. The 37 ways Seacon connector is made of Titanium perfectly compatible
with the Ekinox housing to ensure minimal degradation during long time immersions in salt water.
The cable is composed of two AWG-22 thinned copper conductors for the power supply and four cable triads
for communication signals. Each triad includes four shielded AWG-26 thinned copper twisted pairs.
The following diagrams show the cable overview and internal section for better understanding:
7.5.1.2. Electrical characteristics
General Minimum Insulation Resistance
Rating
Core to Core
> 900 MΩ/km @ 500 V
Core to Screen
> 500 MΩ/km @ 500 V
Screen to Screen
> 10 MΩ/km @ 500 V
26 AWG Screen Twisted Paris (Signals)
Nominal Conductor Resistance
181.10 Ω/km @ 20 °C
Nominal Impedance
100 Ω
Nominal Capacitance
84 pF/m
22 AWG Conductors (Power Supply)
Nominal Conductor Resistance
59.30 Ω/km @ 20 °C
Max Recommended Voltage
500 V
38/42
Figure 7.5 : 9.3.1. CA-AEK-SUB-DPT500-10M
overview
Figure 7.6: 9.3.1. CA-AEK-SUB-DPT500-10M
internal section
Wire triads