Ekinox Subsea
– Hardware Manual
EKINOXSUBSEAHM.1.4
Pin #
Name
Remarks
16
VDD_PWR
Positive power supply
17
Sync In D
Synchronization input signal D
18
GND_PWR
Data Ground return
19
NC
Not connected
20
Port B - RS-422 - Tx+
Port B serial output RS-422
21
Port B - RS-232/RS-422 - Tx-
Port B serial output RS-232/RS-422
22
GND
Power Ground return
23
Sync In B
Synchronization input signal B
24
GND
Power return, the enclosure is isolated from the electrical ground
25
Port D - RS-232/RS-422 - Rx+
Port D serial input RS-232/RS-422
26
Port D - RS-422 - Rx-
Port D serial input RS-422
27
Sync Out B
Synchronization output signal B
28
GND
Data Ground return
29
Sync In A
Synchronization input signal A
30
GND
Data Ground return
31
NC
Not connected
32
Port E - RS-232/RS-422 - Rx+
Port E serial input RS-232/RS-422
33
Port E - RS-422 - Rx-
Port E serial input RS-422
34
Sync In E
Synchronization input signal E
35
GND
Data Ground return
36
Sync Out A
Synchronization output signal A
37
GND
Data Ground return
Note: Unlike the Ekinox surface version the subsea one doesn't provide Sync In C signal. However,
please keep in mind that the synchronization input signals are not hard linked to a serial port.
Note 2: The enclosure is isolated from the electrical grounds. The power and data ground are
internally connected but their pinout must be respected for forward compatibility
Warning: For previous Ekinox Subsea units with product codes EKINOX-#-G4A1-PS-E#-I#, the Sync
In C signal was available instead of the Sync In D.
Please not that it will only impact the Ekinox software configuration as no electrical modification
has been made.
22/42