background image

 

‐ 

6

 ‐ 

4)

 

If

 

key

fob

 

detects

 

any

 

controller

 

started

 

network

 

learn

 

mode,

 

it

 

implement

 

copy

 

controller

 

procedure

 

and

 

LED

 

indicator

 

light

 

on

 

for

 

3

 

seconds

 

after

 

copy

 

successful;

 

If

 

key

fob

 

has

 

not

 

detects

 

any

 

device

 

in

 

60

 

seconds,

 

exit

 

copy

 

controller

 

process

 

and

 

LED

 

indicator

 

goes

 

off.

 

 

[Note:]

   

Key

fob

 

keeps

 

the

 

associated

 

device

 

in

 

association

 

control

 

groups

 

(#2~#4)

 

after

 

copy

 

device

 

to

 

a

 

new

 

controller..

 

[Note:]

 

Press

 

and

 

hold

 

on

 

 

key

 

for

 

2

 

seconds

 

before

 

step

 

3)

 

would

 

terminal

 

copy

 

device

 

procedure.

 

 

„

 

Add

 

key

fob

 

to

 

other

 

Z

Wave

 

network

 

1)

 

Set

 

the

 

master

 

controller

 

into

 

the

 

add

 

device

 

mode

 

(refer

 

to

 

main

 

controller’s

 

operating

 

manual).

 

2)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

on,

 

release

 

all

 

key;

 

3)

 

Press

 

and

 

hold

 

 

key

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

intermittently

 

flash

 

(light

 

on

 

3

 

times

 

in

 

3

 

second),

 

key

fob

 

starts

 

controller

 

learn

 

mode

 

for

 

include

 

to

 

the

 

master

 

controller

 

as

 

a

 

secondary

 

controller;

 

4)

 

During

 

inclusion,

 

LED

 

indicator

 

intermittently

 

flash

 

until

 

inclusion

 

process

 

complete,

 

LED

 

light

 

on

 

3

 

second

 

notice

 

inclusion

 

is

 

successful.

 

After

 

inclusion

 

successful,

 

key

fob

 

stays

 

in

 

wakeup

 

state

 

for

 

30

 

second

 

in

 

order

 

to

 

receive

 

initial

 

wakeup

 

configuration

 

from

 

the

 

master

 

controller.

 

Key

fob

 

stays

 

in

 

inclusion

 

process

 

around

 

60

 

seconds,

 

if

 

there

 

not

 

any

 

controller

 

was

 

detected.

 

[Note:]

   

Key

fob’s

 

learn

 

mode

 

is

 

only

 

available

 

as

 

it

 

has

 

not

 

added

 

any

 

device

 

before

 

or

 

has

 

included

 

in

 

master

 

controller

 

already.

 

Key

fob

 

always

 

ignores

 

Basic

 

Set/Get

 

command

 

requires

 

from

 

other

 

controller.

 

[Note:]

 

Press

 

and

 

hold

 

on

 

 

key

 

for

 

2

 

seconds

 

after

 

step

 

3)

 

would

 

terminal

 

procedure

 

if

 

Z

Wave

 

adding

 

processing

 

has

 

not

 

started.

 

 

„

 

Remove

 

key

fob

 

from

 

other

 

Z

Wave

 

network

 

1)

 

Set

 

the

 

master

 

controller

 

into

 

the

 

exclusion

 

device

 

mode

 

(refer

 

to

 

main

 

controller’s

 

operating

 

manual).

 

2)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

on,

 

release

 

all

 

key;

 

3)

 

Press

 

and

 

hold

 

 

key

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

intermittently

 

flash

 

three

 

times,

 

key

fob

 

starts

 

controller

 

learn

 

mode

 

for

 

exclude

 

from

 

the

 

master

 

controller;

 

4)

 

During

 

exclusion,

 

LED

 

indicator

 

intermittently

 

flash

 

until

 

exclusion

 

process

 

complete,

 

LED

 

light

 

on

 

3

 

second

 

notice

 

inclusion

 

is

 

successful.

 

Key

fob

 

stays

 

in

 

exclusion

 

process

 

around

 

15

 

seconds,

 

if

 

there

 

not

 

any

 

controller

 

was

 

detected.

   

[Note:]

   

Key

fob’s

 

learn

 

mode

 

is

 

only

 

available

 

as

 

it

 

has

 

not

 

added

 

any

 

device

 

before

 

or

 

has

 

included

 

in

 

master

 

controller

 

already.

 

 

„

 

Create

 

associate

 

device

 

to

 

association

 

group

 

of

 

#2~#4

 

together

 

locally

 

1)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

on,

 

release

 

all

 

key;

 

2)

 

Press

 

 

key

 

3

 

times

   

in

 

2

 

seconds,

 

LED

 

indicator

 

blink

 

on

 

1

 

time

 

interval

 

3

 

second

 

(0.5

 

second

 

on,

 

3

 

second

 

off),

 

key

fob

 

starts

 

associate

 

device

 

processing;

 

Summary of Contents for Key-fob

Page 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Page 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Page 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Page 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Page 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Page 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Page 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Page 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...

Reviews: