Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is Class 1 and must be connected to 
an Earth circuit

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is rated at IP65.

This product is not suitable for dimming.

This product is not suitable for location in or near a 
marine or sea environment.

Specification

Voltage: 

240V 50Hz a.c.

Lamp:                 68784: 2 x 1W LED Hi Power Natural White - 200lm
 

68785: 4 x 1W LED Hi Power Natural White - 400lm

IP rating: 

65

Layout

Installation (if used as spike light)

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the connector and the light fitting

•  Avoid locating any cables in positions that would  

cause a hazard. Position cables and junction boxes 
(not supplied) away from areas where they may be 
at risk from being cut, trapped or damaged

•  Cables in walls must be protected using suitable 

conduit or plastic trunking. 

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  This product has special protection against the 

ingress of moisture and is IP65 rated.

•  This product can be used as a spike light. If used 

in this way, ensure that the ground is suitable 
for pushing the spike into, and can support the 
luminaire. Do not install in very wet or boggy areas.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  Wire as detailed below and screw the supplied spike 

into the base of the product and place it into the 
ground. (Fig. 1).

•  Replace fuse or circuit breaker and switch on. Your 

light is now ready for use.

Fig. 1

Installation (if used in concrete or decking)

Existing fittings must be completely removed before installation 
of a new product. Before removing the existing fitting, 

carefully 

note the position of each set of wires

.

•  Undo the 4 hexagonal screws with the supplied hex key 

to detach the back ring plate from the product. Keep the 
4 screws safe for refitting later. N.B once this ring plate is 
removed, there is no need to disassemble the product further. 
(Fig. 2)

•  Place the back ring plate so the 4 fixing holes are flush with 

the ground. Using the back ring plate as a template, mark the 
position of the fixing holes. Drill the fixing holes. Take care 
not to damage any concealed wiring or pipes.

•  Fix the back ring plate into the ground using the supplied 

expanding bolts. N.B. you may need to use a hammer to 
gently tap the bolts into place to start with. Tighten the bolts 
with a spanner to secure in place (Fig. 3).

•  Wire as detailed below.

Fig. 2

Fig. 3

Wiring

•  It is recommended that the Saxby IP68 inline 

connector ref 61515 is used to wire this product. 
Refer to layout diagram.

•  Unscrew the threaded body at the centre of the 

connector from both sides (Fig. 4a).

•  Push the wires into the terminals, observing the 

correct polarity (Fig. 4b). Make sure the gaskets 
are in place to ensure ingress protection.

•  Tighten the screws to secure in place (Fig. 4c).

•  Refit the seals and locking nuts.

Fig. 

4a

Fig. 

4b

Fig. 

4c

Layout