background image

1.
2.

3.
4.
5.

Children, 16 years old and under, should not be allowed to use the Steam Room.
Consult a doctor before using the Steam Room especially for pregnant women or those who have 
a heart condition or undergoing medical treatment.
Immediately stop using the Steam Room if you feel faint, dizzy, and drowsy or experience extreme discomfort.
Do not use the Steam Room if you have been recently drinking alcohol.
Installation of non-skid floor materials or the use of proper footwear is a must at all times when inside the 
Steam Room to prevent slipping that may result to injury. The Steam Room floor and other surfaces could 
become slippery as a result of condensation and moisture.  

IMPORTANT!

  Read the manual provided for use and safety information.

SAWO

SAWO, Inc. SAWO Building Mactan Export Processing Zone 2 Cebu, Philippines 6015

www.sawo.com

!

W A R N I N G 

Summary of Contents for STS120-3

Page 1: ...NUAL STEAMBATH GENERATOR SYSTEMS Congratulations on your purchase of a SAWO Steam Generator Please read the manual carefully before using the steam generator STS60 1 STS60 3 STS45 1 STS45 3 STS90 1 ST...

Page 2: ...discomfort Do not use the Steam Room if you have been recently drinking alcohol Installation of non skid floor materials or the use of proper footwear is a must at all times when inside the Steam Room...

Page 3: ...unqualified persons may void the warranty The Steam Room must be fully enclosed complete with walls door flooring and ceiling We recommend rubber linings e g gaskets for the door to effectively seal t...

Page 4: ...per and automatic safety valve operation DO NOT connect a shut off valve or a plug at safety valve outlet DO NOT connect a shut off valve in steam supply pipe 4 Locating the Steam Generator 1 2 3 4 5...

Page 5: ...generator or one that is capable of being locked in the open position For single phase units use two wire supply source and equipment grounding wire Electrical _______________________________________...

Page 6: ...electrician for electrical installation _________________________________________________ _________________________________________________ TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECT...

Page 7: ...ector for Automatic drain Optional Tandem Cable for connecting 2 5 steam generators in tandem 1 Turn on control Follow specific instruction sheet provided with controls 2 Steam will begin to appear in...

Page 8: ...G Start with one drop to gauge strength and suitability Limit to a maximum of a few drops during a steambathing session Some people may find that the aroma makes dizzy and the user should exit the ste...

Page 9: ...representative if a longer cable is required 2 Drill an 8mm hole in the wall as shown in Diagram 1 Do not oversize or undersize the hole Clean area thoroughly 3 Remove the knock out from the steam ge...

Page 10: ...size or undersize the hole Step 3 Step 4 67 mm 25 mm 25 mm A B C D Wall Wall Do not route the control or temperature sensor wiring inside conduit together with power lines or close to hot water or ste...

Page 11: ...play as a confirmation of the new value you have selected The Set Point indicator shows the desired temperature NOT the actual temperature Temperature can be adjusted in 0 5 degree increments from 40...

Page 12: ...three phase connection and 2 blue wires for single phase connection Remove the nuts and washers that fasten the heating element Detach the heating element from the unit Brush the affected area of the...

Reviews: